Ultimele actualizari :
19/11/2024
Vasodilatator   Nitroglycerin  
Injectabil
Unguente
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Angiopohl Mexic
Dauxona Argentina
Enetege Argentina
Gitrinil Malaezia
Imectin Ecuador
Netronal Iran
Niglinar Argentina
Nitracor Polonia
Nitro Finlanda
Nitro - Pohl Austria, Olanda, Ungaria
Nitro Carino Germania
Nitrocine Egipt, Emiratele Arabe Unite, Iran, Malaezia, Marea Britanie
Nitroglycerin Suedia
Nitroglycerina Chilli
Nitrogray Argentina
Nitroject Canada, Tailanda
Nitrolingual Germania, Grecia
Nitronal Elvetia, Franta, Iran, Irlanda, Marea Britanie, noua Zeelandă, Romania, Turcia
Nitrosol Peru
Nitroven Norvegia
Nysconitrine Belgia, Luxemburg
Perganit Italia
Perlinganit Austria, Elvetia, Finlanda, Germania, Luxemburg, Polonia, Turcia
Solinitrina Spania
Trinitrosan Germania
Bibliografie   Injectabil   Bibliografie : Nitroglycerin  
tip publicare
59 ziar Trissel LA, Gilbert DL, Martinez JF, Kim MC.
Compatibility of remifentanil hydrochloride with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 2192-2196.
63 ziar Marquardt Ed, Lam SSY.
Visual compatibility of fentanyl citrate with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1994 ; 51: 811-812.
90 ziar Driver PS, Jarvi EJ, Gratzer PL.
Stability of nitroglycerin concentrate for injection stored in plastic syringes.
Am J Hosp Pharm 1993 ; 50: 2561-2563.
92 ziar Lee CY, Mauro VF, Alexander KS.
Visual and spectrophotometric determination of compatibility of alteplase and streptokinase with other injectable drugs.
Am J Hosp Pharm 1990 ; 47: 606-608.
93 ziar Hutchings SR, Rusho WJ, Tyler LS.
Compatibility of cefmetazole sodium with commonly used drugs during Y-site delivery.
Am J Health-Syst Pharm 1996 ; 53: 2185-2188.
176 ziar Mantong ML, Marquardt ED.
Visual compatibility of midazolam hydrochloride with selected drugs during simulated Y-site injection.
Am J Health-Syst Pharm 1995 ; 52: 2567-2568.
190 ziar Lee MG.
Sorption of four drugs to polyvinyl chloride and polybutadiene intravenous administration sets.
Am J Hosp Pharm 1986 ; 43: 1945-1950.
192 ziar Peddicord TE, Olsen KM, ZumBrunnen TL, Warner DJ, Webb L.
Stability of high-concentration dopamine hydrochloride, norepinephrine bitartrate, epinephrine hydrochloride, and nitroglycerin in 5% dextrose injection.
Am J Health-Syst Pharm 1997 ; 54: 1417-1419.
194 ziar Loucas SP, Maager P, Mehl B, Loucas ER.
Effect of vehicle ionic strength on sorption of nitroglycerin to a polyvinyl chloride administration set.
Am J Hosp Pharm 1990 ; 47: 1559-1562.
196 ziar Pramar Y, Das Gupta V, Neal Gardner S, Yau B.
Stabilities of dobutamine, dopamine, nitroglycerin and sodium nitroprusside in disposable plastic syringes.
J Clin Pharm Ther 1991 ; 16: 203-207.
198 ziar Gayed AA, Kheshary PR, Hinkle RL.
Visual compatibility of diltiazem injection with various diluents and medications during simulated Y-site injection.
Am J Health-Syst Pharm 1995 ; 52: 516-520.
199 ziar Hassan E, Leslie J, Martir-Herrero ML.
Stability of labetalol hydrochloride with selected critical care drugs during simulated Y-site injection.
Am J Hosp Pharm 1994 ; 51: 2143-2145.
240 ziar Lam XM, Ward CA, de C du M?e CPR.
Stability and activity of alteplase with injectable drugs commonly used in cardiac therapy.
Am J Health-Syst Pharm 1995 ; 52: 1904-1909.
255 ziar Ishisaka DY.
Visual compatibility of fluconazole with drugs given by continuous infusion.
Am J Hosp Pharm 1994 ; 51: 2290,2292.
295 ziar Yamashita SK, Walker SE, Choudhury T, Iazzetta J.
Compatibility of selected critical care drugs during Y-site administration.
Am J Health-Syst Pharm 1996 ; 53: 1048-1051.
299 ziar Trissel LA, Martinez JF, Gilbert DL.
Compatibility of cisatracurium besylate with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1735-1741.
300 ziar Trissel LA, Gilbert DL, Martinez JF.
Compatibility of propofol injectable emulsion with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1287-1292.
301 ziar Trissel LA, Gilbert DL, Martinez JF, Baker MB, Walter WV, Mirtallo JM.
Compatibility of parenteral nutrient solutions with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1295-1300.
314 ziar Chiu MF, Schwartz ML.
Visual compatibility of injectable drugs used in the intensive care unit.
Am J Health-Syst Pharm 1997 ; 54: 64-65.
315 ziar Bahal SM, Lee TJ, McGinnes M, Dobler GL.
Visual compatibility of warfarin sodium injection with selected medications and solutions.
Am J Health-Syst Pharm 1997 ; 54: 2599-2600.
317 ziar Kershaw BP, Monnier HL, Mason JH.
Visual compatibility of premixed theophylline or heparin with selected drugs for IV administration.
Am J Hosp Pharm 1993 ; 50: 1360-1362.
350 ziar Martens HJ, De Goede PN, Van Loenen AC.
Sorption of various drugs in polyvinyl chloride, glass, and polyethylene-lined infusion containers.
Am J Hosp Pharm 1990 ; 47: 369-373.
380 ziar Grillo JA, Gonzalez ER, Ramaiya A, Karnes HT, Wells B.
Chemical compatibility of inotropic and vasoactive agents delivered via a multiple line infusion system.
Crit Care Med 1995 ; 23: 1061-1066.
396 ziar Chilvers MR, Lysne JM.
Visual compatibility of ranitidine hydrochloride with commonly used critical-care medications.
Am J Hosp Pharm 1989 ; 46: 2057-2058.
397 ziar Fong PA, Ward J.
Visual compatibility of intravenous famotidine with selected drugs.
Am J Hosp Pharm 1989 ; 46: 125-126.
398 ziar Jay GT, Fanikos J, Souney PF.
Visual compatibility of famotidine with commonly used critical-care medications during simulated Y-site injection.
Am J Hosp Pharm 1988 ; 45: 1556-1557.
402 ziar Savitsky ME.
Visual compatibility of neuromuscular blocking agents with various injectable drugs during simulated Y-site injection.
Am J Hosp Pharm 1990 ; 47: 820-821.
403 ziar Outman WR, Monolakis J.
Visual compatibility of haloperidol lactate with 0.9% sodium chloride injection or injectable critical-care drugs during simulated Y-site injection.
Am J Hosp Pharm 1991 ; 48: 1539-1541.
479 ziar Min DI, Brown T, HWang GC.
Visual compatibility of tacrolimus with commonly used drugs during simulated Y-site injection.
Am J Hosp Pharm 1992 ; 49: 2964-2966.
524 ziar Farquhar Zanetti LA.
Visual compatibility of diltiazem with commonly used injectable drugs during simulated Y-site administration.
Am J Hosp Pharm 1992 ; 49: 1911.
554 ziar Speaker TJ, Turco SJ, Nardone DA, Miripol JE.
A study of the interaction of selected drugs and plastic syringes.
J Parenter Sci Technol 1991 ; 45: 212-217.
621 ziar Yliruusi JK, Sothmann AG, Laine RH, Rajasilta RA, Kristoffersson ER.
Sorptive loss of diazepam and nitroglycerin from solutions to three types of containers.
Am J Hosp Pharm 1982 ; 39: 1018-1021.
705 ziar Lee YC, Malick W, Amann AH, Baaske DM, Shah JJ, Wagenknecht DM, Carter JE.
Bretylium tosylate admixture compatibility. II : Dopamine, lidocaine, procainamide, and nitroglycerin.
Am J Hosp Pharm 1981 ; 38: 183-187.
708 ziar Baaske DM, Amann AH, Wagenknecht DM, Mooers M, Carter JE, Hoyt HJ, Stoll RG.
Nitroglycerin compatibility with intravenous fluid filters containers, and administration sets.
Am J Hosp Pharm 1980 ; 37: 201-205.
813 ziar Akkermann SR, Zhang H, Mullins RE, Yaughn K.
Stability of milrinone lactate in the presence of 29 critical care drugs and 4 IV solutions.
Am J Health-Syst Pharm 1999 ; 56: 63-68.
857 ziar Kanke M, Eubanks JL, DeLuca PP.
Binding of selected drugs to a “treated” inline filter.
Am J Hosp Pharm 1983 ; 40: 1323-1328.
921 ziar Trissel LA, Gilbert DL, Martinez JF.
Incompatibility and compatibility of amphotericin B cholesteryl sulfate complex with selected other drugs during simulated Y-site administration.
Hosp Pharm 1998 ; 33: 284-292.
963 ziar Schaaf LJ, Tremel LC, Wulf BG, Vernon KK.
Compatibility of enalaprilat with dobutamine, dopamine, heparin, nitroglycerin, potassium chloride and nitroprusside.
J Clin Pharm Ther 1990 ; 15: 371-376.
1027 ziar Wagenknecht DM, Baaske DM, Alam AS, Carter JE, Shah J.
Stability of nitroglycerin solutions in polyolefin and glass containers.
Am J Hosp Pharm 1984 ; 41: 1807-1811.
1036 ziar Hasegawa GR, Eder JF.
Visual compatibility of amiodarone hydrochloride injection with other injectable drugs.
Am J Hosp Pharm 1984 ; 41: 1379-1380.
1041 ziar Hasegawa GR, Eder JF.
Visual compatibility of dobutamine hydrochloride with other injectable drugs.
Am J Hosp Pharm 1984 ; 41: 949-951.
1049 ziar Klamerus KJ, Ueda CT, Newton DW.
Stability of nitroglycerin in intravenous admixtures.
Am J Hosp Pharm 1984 ; 41: 303-305.
1057 ziar Cutie MR.
Compatibility of verapamil hydrochloride injection with commonly used additives.
Am J Hosp Pharm 1983 ; 40: 1205-1207.
1067 ziar Zeidler C, Dettmering D, Schrammel W, Spieteller M.
Compatibility of various drugs used in intensive care medicine in polyethylene, PVC and glass infusion containers.
EJHP 1999 ; 5: 106-110.
1072 ziar Saltsmann CL, Tom CM, Mitchell A, Fan JH, Gailey RA.
Compatibility of levofloxacin with 34 medications during simulated Y-site administration.
Am J Health-Syst Pharm 1999 ; 56: 1458-1459.
1108 ziar Dasta JF, Jacobi J, Wu LS, Sokoloski T, Beckley P, Reilley TE, Howie MB.
Loss of nitroglycerin to cardiopulmonay bypass apparatus.
Crit Care Med 1983 ; 11: 50-52.
1109 ziar Horrow JC, Digregorio J, Barbieri EJ, Rupp E.
Intravenous infusions of nitroprusside, dobutamine, and nitroglycerin are compatible.
Crit Care Med 1990 ; 18: 858-861.
1113 ziar Tracy TS, Bowman L, Black CD.
Nitroglycerin delivery through a polyethylene-lined intravenous administration set.
Am J Hosp Pharm 1989 ; 46: 2031-2035.
1161 ziar Allwood MC.
Sorption of parenteral nitrates during administration with a syringe pump and extension set.
Int J Pharm 1987 ; 39: 183-188.
1166 ziar Sokoloski TD, Wu CC, Burkman AM.
Rapid adsorptive loss of nitroglycerin from aqueous solution to plastic.
Int J Pharm 1980 ; 6: 63-76.
1223 ziar Amann AH, Baaske DM, Wagenknecht DM.
Plastic IV container for nitroglycerin.
Am J Hosp Pharm 1980 ; 37: 618.
1270 ziar Mathot F, Bonnard J, Han P, Bosly J.
IV infusion of glyceryl trinitrate. Study of the sorption on various plastic containers.
J Pharm Belg 1980 ; 35: 389-393.
1353 ziar Nix DE, Tharpe WN, Francisco GE.
Effects of presaturation on nitroglycerin delivery by polyvinyl chloride infusion sets.
Am J Hosp Pharm 1984 ; 41: 1835-1837.
1415 ziar Trissel L.A, Gilbert D.L, Martinez J.F, Baker M.B, Walter W.V, Mirtallo J.M.
Compatibility of medications with 3-in-1 parenteral nutrition admixtures.
JPEN 1999 ; 23: 67-74.
1472 ziar Salomies HEM, Heinonen RM, Toppila MAI.
Sorptive loss of diazepam, nitroglycerin and warfarin sodium to polypropylene-lined infusion bags (Softbags).
Int J Pharm 1994 ; 110: 197-201.
1508 ziar Voirol P, Berger-Gryllaki M, Pannatier A, Eggimann P, Sadeghipour F.
Visual compatibility of insulin aspart with intravenous drugs frequently used in ICU.
EJHP 2015 ;22:123-124.
1512 Laborator Tirofiban (Aggrastat®) - Summary of Product Characteristics
Beacon Pharmaceuticals Ltd 2015
1522 Laborator Macoflex N®
Maco Pharma 2001
1603 ziar Bergquist PA, Manas D, Hunke WA, Reed RA.
Stability and compatibility of tirofiban hydrochloride during simulated Y-site administration with other drugs.
Am J Health-Syst Pharm 2001 ; 58: 1218-1223.
1625 ziar Trissel LA, Saenz C, Williams YW, Ingram D.
Incompatibilities of lansoprazole injection with other drugs during simulated Y-site coadministration.
Int J Pharm Compound 2001 ; 5: 314-321.
1703 ziar Schuster F, Bernard R.
Kompatibilität von enalaprilat i.v. mit ausgewählten arzneimitteln.
Krankenhauspharmazie 1995 ; 16: 101-103.
1712 ziar Trissel LA, Saenz CA.
Compatibility screening of Precedex during simulated Y-site administration with other drugs.
Int J Pharm Compound 2002 ; 6: 230-233.
1713 ziar Trissel LA, Saenz CA.
Compatibility screening of bivalirudin during simulated Y-site administration with other drugs.
Int J Pharm Compound 2002 ; 6: 311-315.
1721 ziar Trissel LA, Williams KY, Baker MB.
Compatibility screening of Hextend during simulated Y-site administration with other drugs.
Int J Pharm Compound 2001 ; 5: 69-72.
1801 ziar Feddema S, Rusho WJ, Tyler LS, Barker B.
Physical compatibility of vasopressin with medications commonly used in cardiac arrest.
Am J Health-Syst Pharm 2003 ; 60: 1271-1272.
1803 ziar Trissel, LA, Saenz CA, Ogundele OB, Ingram D, Baker MB.
Compatibility of fenoldopam mesylate with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2003 ; 60: 80-85.
1902 ziar Walker SE, Wyllie A, Law S.
Physical compatibility of pantoprazole with selected medications during simulated Y-site administration.
Can J Hosp Pharm 2004 ; 57, 2: 90-96.
1925 ziar Trissel LA , Williams KY, Gilbert DL.
Compatibility screening of linezolid injection during simulated Y-site administration with other drugs and infusion solutions.
J Am Pharm Assoc 2000 ; 40: 515-519.
1960 ziar Kambia NK, Dine T, Dupin-Spriet T, Gressier B, Luycks M, Goudaliez F, Brunet C.
Compatibility of nitroglycerin, diazepam and chlorpromazine with a new multilayer material for infusion containers.
J Pharm Biomed Anal 2005 ; 37: 259-264.
1963 ziar Honisko ME, Fink JM, Militello MA, Mauro VF, Alexander KS.
Compatibility of argatroban with selected cardiovascular agents.
Am J Health-Syst Pharm 2004 ; 61: 2415-2418.
1980 ziar Hansen HC, Spillum A.
Loss of nitroglycerin during passage through two different infusion sets.
Act Pharm Nord 1991 ; 3, 3: 131-136.
2018 ziar Veggeland T.
Visual compatibility of clonidine with selected drugs.
Am J Health-Syst Pharm 2005 ; 62: 1968-1969.
2090 ziar Pere H, Chasse V, Forest JM, Hildgen P.
Compatibility of injectable pantoprazole in Y-site administration.
Pharmactuel 2004 ; 37: 193-196.
2108 ziar Trusley C, Kupiec TC, Trissel LA.
Compatibility of micafungin injection with other drugs during simulated Y-site co-administration.
Int J Pharm Compound 2006 ; 10: 230-232.
2109 ziar Pelletier E, Forest JM, Hildgen P.
Compatibilité de la kétamine injectable lors de l’administration en dérivé avec d’autres médicaments usuels.
Pharmactuel 2006 ; 39: 71-75.
2146 ziar Trissel LA, Xu QA, Baker M.
Drug compatibility with new polyolefin infusion solution containers.
Am J Health-Syst Pharm 2006 ; 63: 2379-2382.
2324 ziar Treleano A, Wolz G, Brandsch R, Welle F.
Investigation into the sorption of nitroglycerin and diazepam into PVC tubes and alternative tube materials during application
Int J Pharm 2009 ; 369, 1-2 : 30-37
2346 ziar Newland A.M, Mauro V.F, Alexander K.S.
Physical compatibility of metoprolol tartrate injection with selected cardiovascular agents
Am J Health-Syst Pharm 2009 ; 66: 986-987.
3012 ziar Sullivan T, Forrest J.M, Leclair G.
Compatibility of Cloxacillin Sodium with Selected Intravenous Drugs During Simulated Y-Site Administration
Hosp Pharm 2015 ; 50, 3: 214-220.
3134 ziar Perez Jua En, Maqueda Palau M, Arévalo Rubert Mt, Ribas Nicolau B, Amoros Cerdà SM.
Compatibilidad visual y física de la furosemida en mezclas intravenosas para perfusión continua.
Enferm Intensiva 2010 ; 21: 96-103.
3152 ziar Kumar A, Mann HJ.
Visual compatibility of oritavancin diphosphate with selected coadministered drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2010 ; 67: 1640-1644.
3210 ziar Jasti Bhaskara R, Saraf Poonam.
Compatibility of Parenteral Furosemide with Seventeen Secondary Drugs Used in Standard Concentrations.
Int J Pharm Compound 2011 ; 15, 3: 259-261.
3212 ziar Ribas Nicolau, B.; P?rez Juan, E.; Amor?s Cerd?, S.M.; Ar?valo Rubert, M.J.; Maqueda Palau, M.
Compatibilidad física del bicarbonato sódico con fármacos de uso frecuente en la unidad de cuidados intensivos.
Enferm Intensiva 2011 ;22:78-82.
3216 ziar Legris ME, Valiquette ME, Lavoie A, Forest JM, Leclair G.
Compatibilité physique par évaluation visuelle du salbutamol injectable lors de son administration en Y.
Pharmactuel 2011 ; 44, 1 : 14-18
3372 ziar Hanci V, Ali Kiraz H, Ömür D, Ekin S, Uyan B, Yurtlu B.S.
Precipitation in Gallipoli: Sugammadex / Amiodarone & Sugammadex / Dobutamine & Sugammadex / Protamine.
Rev Bras Anestesiol 2013 ; 63, 1: 163-166.
3408 ziar Tollec S, Touzin K, Pelletier E, Forest J.M.
Evaluation visuelle de la compatibilité physique de la naloxone avec d’autres médicaments intraveineux usuels.
Pharmactuel 2013 ; 46, 1 : 16-21.
3464 ziar Monica Maqueda-Palau, Eva Pérez-Juan, Maria Josep Arévalo-Rubert, Sylvia Monica Amoros-Cerda, Bàrbara Ribas-Nicolau.
Compatibilidad física de la amiodarona en perfusión continua
Enferm Clin 2011 21:25-29.
3465 ziar E. P?rez Juan, M. Maqueda Palau, M. Ar?valo Rubert, B. Ribas Nicolau, S.M. Amor?s Cerd?.
Compatibilidad visual y física de la furosemida en mezclas intravenosas para perfusión continua.
Enferm Intensiva 2010 ;21:96-103.
3466 ziar B. Ribas Nicolau, E. P?rez Juan, S.M. Amor?s Cerd?, M.J. Ar?valo Rubert, M. Maqueda Palau.
Compatibilidad física del bicarbonato sódico con fármacos de uso frecuente en la unidad de cuidados intensivos
Enferm Intensiva 2011 ;22:78-82.
3536 ziar McCluskey S V, Vu N, Rueter J.
Stability of Nitroglycerin 100 mcg/mL Stored in Polypropylene Syringes
Int J Pharm Compound 2013 ; 17, 6: 515-519
3715 ziar Mauro V.F, Howard M.S, Boddu S.H.S, Churchwell M.D.
Compatibility of conivaptan injection with select cardiovascular medications.
Am J Health-Syst Pharm 2014 ; 71:1534-1535
3766 ziar Forrest J.M, Hildgen P.
Compatibilité de l’acétylcystéine injectable lors de son administration en Y avec d’autres médicaments usuels
Pharmactuel 2014 ; 47, 3 : 161-165.
3767 ziar Legris M.E, Lavoie A, Forrest J.M, Hildgen P.
Compatibilité par évaluation visuelle du thiopental injectable lors de son administration en Y avec des médicaments usuels.
Pharmactuel 2014 ; 47, 3 : 167-172.
3823 ziar Juan E.P, Palau M.M, Cerd? S.A, Rubert M.A, Nicolau B.R.
Compatibilité physique de médicaments administrés dans l’unité de soins intensifs
Pharmactuel 2015 ; 48, 3 : 146-152.
3824 ziar Boudi S, Roy H, Forest JM, Leclair G.
Compatibilité physique de l'association amoxicilline-acide clavulanique en injection avec plusieurs autres médicaments lors d'une administration en Y.
Pharmactuel 2023 2023;56,3:91-98
3827 poster Ghazi I.M, Hamada Y, Nicolau D.P.
Compatibility of tedizolid phosphate with selected intravenous drugs via simulated Y-site conditions.
ASHP Midyear 2015
3828 poster Thabit A.K, Hamada Y, Nicolau D.P.
Ceftozolane/tazobactam physical compatibility during simulated Y-site administration.
ASHP Midyear 2015
3829 poster So W, Kim L, Thabit A.K, Nicolau D.P, Kuti J.L.
Compatibility of isavunazonium sulfate during simulated Y-site administration.
ASHP Midyear 2015
3932 Laborator Hydroxocobalamine (Cyanokit®) - Résumé des caractéristiques du produit
Serb Laboratoire 2015
3934 Laborator Eptifibatide (Integrilin®) - Résumé des caractéristiques du produit
GlaxoSmithKline Laboratoire 2016
3964 ziar Audet M.A, Forest E, Friciu M, Forest J.M, Leclair G.
Compatibilité du citrate de caféine injectable avec plusieurs autres médicaments.
Pharmactuel 2017 ; 50,1 : 27-33.
4055 ziar Monogue M, Almarzoky Abuhussain S, Kuti J, Nicolau D.
Physical compatibility of fosfomycin for injection with select i.v. drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2018 , 75, 1:36-44
4119 poster Marcoz N, Ing H, Sautter AM, Saadi JF, Roulin JF, Bonnabry P.
Stabilité et compatibilité de solutions injectables d'amiodarone (Cordarone®)
Hôpitaux Universitaire de Genève 2004
4145 ziar Asempa T.E, Avery L.M, Kidd J.M, Kuti J.L, Nicolau D.P.
Physical compatibility of plazomicin with select i.v. drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2018 ;75,14:1048-1056
4319 ziar Lessard J-J, Caron E, Schérer H, Forest J-M, Leclair G.
Compatibility of Y-site Injection of Meropenem Trihydrate With 101 Other Injectable Drugs.
Hosp Pharm 2020 ; 55, 5: 332-337.
4389 ziar Côté K, Correal F, Metras M.E, Friciu M, Forest J.M, Leclair G.
Compatibilité physique des médicaments administrés en Y aux soins intensifs, en particulier la dexmédétomidine, le lévosimendan et la kétamine.
Pharmactuel 2019 ;52,4:206-213
4433 ziar Ghazi I.M, El Nekidy W.S, Sood A, Dulku A, Patel R, Patel K.
Y-site Administration of Imipenem/Cilastatin/ Relebactam With Common Intravenous Medications
Clin Ther 2020 ; 42, 3: 475-485.
4528 ziar Lu J, Liu Q, Kupiec T, Vail H, Lunch L, Fam D, Vu N.
Physical Compatibility of Cefiderocol with Selected Intravenous Drugs During Simulated Y-site Administration.
Int J Pharm Compound 2021 ;25,1:52-61
4571 Laborator Levosimendan (Simdax 2.5 mg/ml) - Summary of Product Characteristics
Orion Pharma 2010
4603 ziar Vallée M, Barthélémy I, Friciu M, Pelletier E, Forest J.M, Benoit F, Leclair G.
Compatibility of Lactated Ringer’s Injection With 94 Selected Intravenous Drugs During Simulated Y-site Administration.
Hosp Pharm 2021 ; 56, 4: 228-234.
4742 ziar Macoviciuc M, Nguyen C, Forest J-M, Leclair G.
Compatibilité physique de l’acétaminophène injectable avec 102 autres médicaments lors d’une administration en Y.
Pharmactuel 2022 ; 55, 4: 247-255.
4801 ziar Ruiz V, Yuwei Shen Y, Abouelhassan Y, Fouad A, Nicolau D, Kuti J.
Physical compatibility of sulbactam/durlobactam with select intravenous drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2024 ;51,1:

  Mentions Légales