Ultimele actualizari :
19/11/2024
Anxiolitic   Diazepam  
Injectabil
Soluţie orală Supozitoare
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Ansiolin Italia
Bamyl Chilli
Compaz Brazilia
Daiv Argentina, Columbia
Diactal Argentina
Diapam Finlanda, Turcia
Diazem Turcia
Diazemuls Canada, Italia, Marea Britanie, Olanda
Diazep Germania
Diazepam Australia, Canada, Columbia, Ecuador, Germania
Faustan Germania
Gewalcalm Austria
Kiatrium Brazilia
Noan Italia
Normabel Croatia
Ortopsique Ecuador
Pacitran Peru
Pax Africa de Sud
Relanium Polonia
Rupediz Argentina
Stedon Grecia
Stesolid Arabia Saudita, Danemarca, Elvetia, Germania, Islanda, Norvegia, Suedia
Sunzepan Mexic
Tranject Africa de Sud
Valium Africa de Sud, Arabia Saudita, Austria, Belgia, Brazilia, Columbia, Ecuador, Egipt, Elvetia, Emiratele Arabe Unite, Franta, Germania, Italia, Luxemburg, Maroc, Mexic, Olanda, Portugalia, Spania, Venezuela
Bibliografie   Injectabil   Bibliografie : Diazepam  
tip publicare
55 ziar Smith A, Bird G.
The compatibility of diazepam with infusion fluids and their containers.
J Clin Hosp Pharm 1982 ; 7: 181-186.
58 ziar Parker WA.
Physical compatibility of ranitidine HCl with preoperative injectable medications.
Can J Hosp Pharm 1985 ; 38: 160-161.
59 ziar Trissel LA, Gilbert DL, Martinez JF, Kim MC.
Compatibility of remifentanil hydrochloride with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 2192-2196.
73 ziar Lor E, Takagi J.
Visual compatibility of foscarnet with other injectable drugs.
Am J Hosp Pharm 1990 ; 47: 157-159.
93 ziar Hutchings SR, Rusho WJ, Tyler LS.
Compatibility of cefmetazole sodium with commonly used drugs during Y-site delivery.
Am J Health-Syst Pharm 1996 ; 53: 2185-2188.
190 ziar Lee MG.
Sorption of four drugs to polyvinyl chloride and polybutadiene intravenous administration sets.
Am J Hosp Pharm 1986 ; 43: 1945-1950.
198 ziar Gayed AA, Kheshary PR, Hinkle RL.
Visual compatibility of diltiazem injection with various diluents and medications during simulated Y-site injection.
Am J Health-Syst Pharm 1995 ; 52: 516-520.
226 ziar Walker SE, DeAngelis C, Iazzetta J.
Stability and compatibility of combinations of hydromorphone and a second drug.
Can J Hosp Pharm 1991 ; 44: 289-295.
266 ziar Patel PR.
Compatibility of meropenem with commonly used injectable drugs.
Am J Health-Syst Pharm 1996 ; 53: 2853-2855.
299 ziar Trissel LA, Martinez JF, Gilbert DL.
Compatibility of cisatracurium besylate with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1735-1741.
300 ziar Trissel LA, Gilbert DL, Martinez JF.
Compatibility of propofol injectable emulsion with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1287-1292.
348 ziar Hancock BG, Black CD.
Effect of a polyethylene-lined administration set on the avaibility of diazepam injection.
Am J Hosp Pharm 1985 ; 42: 335-339.
350 ziar Martens HJ, De Goede PN, Van Loenen AC.
Sorption of various drugs in polyvinyl chloride, glass, and polyethylene-lined infusion containers.
Am J Hosp Pharm 1990 ; 47: 369-373.
351 ziar Yliruusi JK, Uotila JA, Kristoffersson ER.
Effect of flow rate and type of IV container on adsorption of diazepam to IV administration systems.
Am J Hosp Pharm 1986 ; 43: 2795-2799.
352 ziar Yliruusi JK, Uotilo JA, Kristoffersson ER.
Effect of tubing length on adsorption of diazepam to polyvinyl chloride administration sets.
Am J Hosp Pharm 1986 ; 43: 2789-2794.
402 ziar Savitsky ME.
Visual compatibility of neuromuscular blocking agents with various injectable drugs during simulated Y-site injection.
Am J Hosp Pharm 1990 ; 47: 820-821.
476 ziar Knapp AJ, Mauro VF, Alexander KS.
Incompatibility of ketorolac tromethamine with selected postoperative drugs.
Am J Hosp Pharm 1992 ; 49: 2960-2962.
496 ziar Lor E, Sheybani T, Takagi J.
Visual compatibility of fluconazole with commonly used injectable drugs during simulated Y-site administration.
Am J Hosp Pharm 1991 ; 48: 744-746.
616 ziar Jump WG, Plaza VM, Poremba A.
Compatibility of nalbuphine hydrochloride with other preoperative medications.
Am J Hosp Pharm 1982 ; 39: 841-843.
621 ziar Yliruusi JK, Sothmann AG, Laine RH, Rajasilta RA, Kristoffersson ER.
Sorptive loss of diazepam and nitroglycerin from solutions to three types of containers.
Am J Hosp Pharm 1982 ; 39: 1018-1021.
660 ziar Michaels MR, Stauffer GL, Haas DP.
Propofol compatibility with other intravenous drug products - Two new methods of evaluating IV emulsion compatibility.
Ann Pharmacotherapy 1996 ; 30: 228-232.
711 ziar Cloyd JC, Vezeau C, Miller KW.
Avaibility of diazepam from plastic containers.
Am J Hosp Pharm 1980 ; 37: 492-496.
712 ziar Parker WA, MacCara ME.
Compatibility of diazepam with intravenous fluid containers and administration sets.
Am J Hosp Pharm 1980 ; 37: 496-500.
730 ziar Allen LV, Saul Levinson R, Phisutsinthop D.
Compatibility of various admixtures with secondary additives at Y-injection site of intravenous administration sets.
Am J Hosp Pharm 1977 ; 34: 939-943.
731 ziar Morris ME.
Compatibility and stability of diazepam injection following dilution with intravenous fluids.
Am J Hosp Pharm 1978 ; 35: 669-672.
921 ziar Trissel LA, Gilbert DL, Martinez JF.
Incompatibility and compatibility of amphotericin B cholesteryl sulfate complex with selected other drugs during simulated Y-site administration.
Hosp Pharm 1998 ; 33: 284-292.
939 ziar Gilbar PJ, Groves CF.
Visual compatibility of total parenteral nutrition solution (Synthamin 17 Premix*) with selected drugs during simulated Y-site injection.
Aust J Hosp Pharm 1994 ; 24: 167-170.
1041 ziar Hasegawa GR, Eder JF.
Visual compatibility of dobutamine hydrochloride with other injectable drugs.
Am J Hosp Pharm 1984 ; 41: 949-951.
1057 ziar Cutie MR.
Compatibility of verapamil hydrochloride injection with commonly used additives.
Am J Hosp Pharm 1983 ; 40: 1205-1207.
1067 ziar Zeidler C, Dettmering D, Schrammel W, Spieteller M.
Compatibility of various drugs used in intensive care medicine in polyethylene, PVC and glass infusion containers.
EJHP 1999 ; 5: 106-110.
1102 ziar Cossum PA, Roberts MS.
Availability of isosorbide dinitrate, diazepam and chlormethiazole, from i.v. delivery systems.
Eur J Clin Pharmacol 1981 ; 19: 181-185.
1173 ziar Kowaluk EA, Roberts MS, Blackburn HD, Polack AE.
Interactions between drugs and polyvinyl chloride infusion bags.
Am J Hosp Pharm 1981 ; 38: 1308-1314.
1182 ziar Mason NA, Cline S, Hyneck ML, Berardi RR, Ho NFH, Flynn GL.
Factors affecting diazepam infusion: solubility, administration-set composition, and flow rate.
Am J Hosp Pharm 1981 ; 38: 1449-1454.
1199 ziar Smith FM, Nuessle NO.
Stability of diazepam injection repackaged in glass unit-dose syringes.
Am J Hosp Pharm 1982 ; 1687-1690.
1200 ziar Chaudry IA, Bruey KP, Hurlburt LE, Oden EM.
Compatibility of netilmycin sulfate injection with commonly used intravenous injections and additives.
Am J Hosp Pharm 1981 ; 38: 1737-1742.
1232 ziar Beatson C, Taylor A.
A physical compatibility study of furosemide & flucloxacillin injections.
Br J Pharm Pract 1987 ; 9: 223-226, 236.
1269 ziar DeMuynck C, De Vroe C, Remon JP, Colardyn F.
Binding of drugs to end-line filters: a study of four commonly administered drugs in intensive care units.
J Clin Pharm Ther 1988 ; 13: 335-340.
1271 ziar Mathot F, Bonnard J, Paris P, Bosly J.
Reliable continuous IV perfusion system for diazepam.
J Pharm Belg 1982 ; 37: 153-156.
1366 ziar Jeglum EL, Winter E, Kotos M.
Nafcillin sodium incompatibility with acidic solutions.
Am J Hosp Pharm 1981 ; 38: 462,464.
1424 ziar Gottwald MD, Akerd LC, Liu PK, Orsulak PJ, Corry M, Bacchetti P, Fields SM, Loxenstein DH, Alldredge BK.
Prehospital stability of diazepam and lorazepam.
Am J Emerg Med 1999 ; 17: 333-337.
1438 ziar Souney PF, Solomon MA, Stancher D.
Visual compatibility of cimetidine hydrochloride wih common preoperative injectable medications.
Am J Hosp Pharm 1984 ; 41: 1840-1841.
1472 ziar Salomies HEM, Heinonen RM, Toppila MAI.
Sorptive loss of diazepam, nitroglycerin and warfarin sodium to polypropylene-lined infusion bags (Softbags).
Int J Pharm 1994 ; 110: 197-201.
1512 Laborator Tirofiban (Aggrastat®) - Summary of Product Characteristics
Beacon Pharmaceuticals Ltd 2015
1522 Laborator Macoflex N®
Maco Pharma 2001
1603 ziar Bergquist PA, Manas D, Hunke WA, Reed RA.
Stability and compatibility of tirofiban hydrochloride during simulated Y-site administration with other drugs.
Am J Health-Syst Pharm 2001 ; 58: 1218-1223.
1625 ziar Trissel LA, Saenz C, Williams YW, Ingram D.
Incompatibilities of lansoprazole injection with other drugs during simulated Y-site coadministration.
Int J Pharm Compound 2001 ; 5: 314-321.
1662 ziar Trissel LA, Saenz CA, Ingram DS, Ogundele AB.
Compatibility screening of oxaliplatin during simulated Y-site administration with other drugs.
J Oncol Pharm Practice 2002 ; 8: 33-37.
1712 ziar Trissel LA, Saenz CA.
Compatibility screening of Precedex during simulated Y-site administration with other drugs.
Int J Pharm Compound 2002 ; 6: 230-233.
1713 ziar Trissel LA, Saenz CA.
Compatibility screening of bivalirudin during simulated Y-site administration with other drugs.
Int J Pharm Compound 2002 ; 6: 311-315.
1721 ziar Trissel LA, Williams KY, Baker MB.
Compatibility screening of Hextend during simulated Y-site administration with other drugs.
Int J Pharm Compound 2001 ; 5: 69-72.
1803 ziar Trissel, LA, Saenz CA, Ogundele OB, Ingram D, Baker MB.
Compatibility of fenoldopam mesylate with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2003 ; 60: 80-85.
1925 ziar Trissel LA , Williams KY, Gilbert DL.
Compatibility screening of linezolid injection during simulated Y-site administration with other drugs and infusion solutions.
J Am Pharm Assoc 2000 ; 40: 515-519.
1960 ziar Kambia NK, Dine T, Dupin-Spriet T, Gressier B, Luycks M, Goudaliez F, Brunet C.
Compatibility of nitroglycerin, diazepam and chlorpromazine with a new multilayer material for infusion containers.
J Pharm Biomed Anal 2005 ; 37: 259-264.
1974 ziar Chandler SW, Trissel LA, Weinstein SM
Combined administration of opoids with selected drugs to manage pain and other cancer symptoms initial safety screening for compatibility.
J Pain Symptom Manage 1996 ; 12, 3: 168-171.
2087 ziar Ferreira E, Forest JM, Hildgen P.
Compatibility of dimenhydrinate injectable by Y administration.
Pharmactuel 2004 ; 37: 17-20.
2090 ziar Pere H, Chasse V, Forest JM, Hildgen P.
Compatibility of injectable pantoprazole in Y-site administration.
Pharmactuel 2004 ; 37: 193-196.
2262 ziar Brammer MK, Chan P, Heatherly K, Trusley C, Kupiec TC, Trissel LA, Psathas PA, Gilmor T, Schaufelberger D.
Compatibility of doripenem with other drugs during simulated Y-site administratioN
Am J Health-Syst Pharm 2008 ; 65: 1261-1265.
2269 ziar Chan P, Bishop A, Kupiec TC, Trissel LA, Gole D, Jimidar IM, Vermeersch H.
Compatibility of ceftobiprole medocaril with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2008 ; 65, 16: 1545-1551.
2324 ziar Treleano A, Wolz G, Brandsch R, Welle F.
Investigation into the sorption of nitroglycerin and diazepam into PVC tubes and alternative tube materials during application
Int J Pharm 2009 ; 369, 1-2 : 30-37
3012 ziar Sullivan T, Forrest J.M, Leclair G.
Compatibility of Cloxacillin Sodium with Selected Intravenous Drugs During Simulated Y-Site Administration
Hosp Pharm 2015 ; 50, 3: 214-220.
3184 Laborator
Hyaluronidase (Hyalase®) - Summary of Product characteristics.
CP Pharmaceuticals 2005
3216 ziar Legris ME, Valiquette ME, Lavoie A, Forest JM, Leclair G.
Compatibilité physique par évaluation visuelle du salbutamol injectable lors de son administration en Y.
Pharmactuel 2011 ; 44, 1 : 14-18
3249 ziar Singh BM, Dedhiya MG, Dinunzio J, Chan P, Kupiec TC, Trissel LA, Laudano JB.
Compatibility of ceftaroline fosamil for injection with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2011 ; 68: 2163-2169.
3332 Laborator Tigecycline (Tigacyl®) - Summary of Product characteristics
Pfizer 2012
3408 ziar Tollec S, Touzin K, Pelletier E, Forest J.M.
Evaluation visuelle de la compatibilité physique de la naloxone avec d’autres médicaments intraveineux usuels.
Pharmactuel 2013 ; 46, 1 : 16-21.
3474 Laborator Fluorouracil - Summary of Product Characteristics
Accord Healthcare Limited 2009
3501 Laborator Ketamine hydrochloride (Ketalar®) - Summary of Product Characteristics
Pfizer 2011
3521 Laborator Tramadol® - Summary of Product Characteristics.
Beacon Pharmaceuticals 2012
3539 Laborator Bivalirudin (Angiox®) - Summary of Product Characteristics.
The Medecines Company 2013
3540 Laborator Heparin sodium - Summary of Product Characteristics.
Wockhardt 2010
3560 Laborator Linezolid (Zyvox®) - Summary of Product Characteristics
Pharmacia 2013
3564 Laborator Rocuronium B Braun - Résumé des caractéristiques du produit.
B Braun 2012
3571 ziar Anderson C, Boehme S, Ouellette J, Stidham C, MacKay M.
Physical and Chemical Compatibility of Injectable Acetaminophen During Simulated Y-Site Administration.
Hosp Pharm 2014 ; 49, 1: 42-47.
3599 Laborator Glycopyrrolate Injection U.S.P. - Summary of Product Characteristics
Amco Amdipharm Mercry 2013
3607 Laborator Esmolol hydrochloride for injection - Summary of Product Characteristics
AOP Orphan Pharmaceuticals AG 2013
3614 Laborator Nicardipine Injection - Summary of Product Characteristics
American Regent Inc 2013
3617 Laborator Hyaluronidase (Hyalase®) - Summary of Product Characteristics
Wockhardt 2011
3672 Laborator Nalbuphine Mylan - Résumé des caractéristiques du produit
Mylan SAS 2016
3766 ziar Forrest J.M, Hildgen P.
Compatibilité de l’acétylcystéine injectable lors de son administration en Y avec d’autres médicaments usuels
Pharmactuel 2014 ; 47, 3 : 161-165.
3767 ziar Legris M.E, Lavoie A, Forrest J.M, Hildgen P.
Compatibilité par évaluation visuelle du thiopental injectable lors de son administration en Y avec des médicaments usuels.
Pharmactuel 2014 ; 47, 3 : 167-172.
3824 ziar Boudi S, Roy H, Forest JM, Leclair G.
Compatibilité physique de l'association amoxicilline-acide clavulanique en injection avec plusieurs autres médicaments lors d'une administration en Y.
Pharmactuel 2023 2023;56,3:91-98
3885 ziar Su-Eon Jin, Siwon You, Seungho Jeon, Sung-Joo Hwang.
Diazepam sorption to PVC- and non-PVC-based tubes in administration sets with quantitative determination using a high-performance liquid chromatographic method.
Int J Pharm 2016 ; 506 : 414-419.
3932 Laborator Hydroxocobalamine (Cyanokit®) - Résumé des caractéristiques du produit
Serb Laboratoire 2015
3941 Laborator Nicardipine - Summary of Product Characteristics
Concordia International 2017
3964 ziar Audet M.A, Forest E, Friciu M, Forest J.M, Leclair G.
Compatibilité du citrate de caféine injectable avec plusieurs autres médicaments.
Pharmactuel 2017 ; 50,1 : 27-33.
4154 Laborator Bleomycin sulfate- Summary of Product Characteristics
Accord Health Care 2018
4319 ziar Lessard J-J, Caron E, Schérer H, Forest J-M, Leclair G.
Compatibility of Y-site Injection of Meropenem Trihydrate With 101 Other Injectable Drugs.
Hosp Pharm 2020 ; 55, 5: 332-337.
4428 ziar Rashed S.M, Sweatman T.W, Thoma L, Hovinga C.A, Phelps S.J.
Chemical Compatibility of Depacon® with Medications Frequently Administered by Intravenous Y-Site Delivery in Patients with Epilepsy or Head Trauma.
J Pediatr Pharmacol Ther 2004 ; 9, 2: 126-132.
4435 ziar Hanifah S, Nugroho B.H, Chabib L.
Compatibility of acetaminophen with central nervous system medications during simulated Y-site injection.
Anaesthesiol Intensive Ther 2020 ; 52, 1: 23-27.
4603 ziar Vallée M, Barthélémy I, Friciu M, Pelletier E, Forest J.M, Benoit F, Leclair G.
Compatibility of Lactated Ringer’s Injection With 94 Selected Intravenous Drugs During Simulated Y-site Administration.
Hosp Pharm 2021 ; 56, 4: 228-234.
4650 Laborator Ceftobiprole (Zevtera 500 mg powder for concentrate for solution for infusion.) Summary of Product Characteristics, Advanz Pharma updated 4 aug 2021.
Advanz Pharma 2021
4700 Laborator Esketamine 25 mg/mL solution for injection/infusion. - Summary of Product Characteristics
AS Kalceks 2022
4742 ziar Macoviciuc M, Nguyen C, Forest J-M, Leclair G.
Compatibilité physique de l’acétaminophène injectable avec 102 autres médicaments lors d’une administration en Y.
Pharmactuel 2022 ; 55, 4: 247-255.

  Mentions Légales