Last update :
28/04/2024
References   References 1975  
Type : Journal
Web link : http://www.ijpc.com/Abstracts/Abstract.cfm?ABS=2201

Research teams : Houston - M.D.Anderson Cancer Center
Authors : Trissel LA, Xu QA.
Title : Physical and chemical stability of palonosetron hydrochloride with lorazepam and midazolam hydrochloride during simulated Y-site administration.
Reference : Int J Pharm Compound ; 9, 3: 235-237. 2005

Level of Evidence : 
Level of evidence A+
Physical stability : 
Visual examination Turbidimetry Particle counting 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
Stability defined as 95% of the initial concentration
Other methods : 
Comments : 

List of drugs
InjectionLorazepam Anxiolytic
Compatible 0,5 mg/ml + InjectionPalonosetron hydrochloride 50 µg/ml + Glucose 5%
InjectionMidazolam hydrochloride Anxiolytic
Compatible 2 mg/ml + InjectionPalonosetron hydrochloride 50 µg/ml + Glucose 5%
InjectionPalonosetron hydrochloride Antiemetic
Compatible 50 µg/ml + InjectionLorazepam 0,5 mg/ml + Glucose 5%
Compatible 50 µg/ml + InjectionMidazolam hydrochloride 2 mg/ml + Glucose 5%
Stability of mixtures
Glass Glucose 5% 20°C-25°C Not specified
Injection Palonosetron hydrochloride 25 µg/ml
Injection Lorazepam 0,25 mg/ml
4 Hour
Glass Glucose 5% 20°C-25°C Not specified
Injection Palonosetron hydrochloride 25 µg/ml
Injection Midazolam hydrochloride 1 mg/ml
4 Hour

  Mentions Légales