Ultimo aggiornamento :
19/11/2024
Antibiotico   Rifampicin  
Iniezione
Soluzione orale
Stabilità in soluzione Stabilità in miscela Fattori che influenzano la stabilità Compatibilità metodo di iniezione Bibliografia pdf
   Struttura chimica  

Nome commerciale   Nome commerciale     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Eremfat Austria, Germania
Rif Turchia
Rifa Germania
Rifadin Australia, Gran Bretagna, Iran, Irlanda, Italia, nuova Zelanda, Paesi Bassi, Stati Uniti d’America, Svezia
Rifadine Belgio, Francia, Marocco
Rifaldin Iran, Spagna
Rifampicin Germania
Rifampicina Argentina, Ecuador
Rifampin Stati Uniti d’America
Rifoldin Austria
Rimactan Svizzera
Rimactane Irlanda
Bibliografia   Iniezione   Bibliografia : Rifampicin  
tipo pubblicazione
198 Rivista Gayed AA, Kheshary PR, Hinkle RL.
Visual compatibility of diltiazem injection with various diluents and medications during simulated Y-site injection.
Am J Health-Syst Pharm 1995 ; 52: 516-520.
263 Rivista Pearson SD, Trissel LA.
Stability and compatibility of minocycline hydrochloride and rifampicin in intravenous solutions at various temperatures.
Am J Hosp Pharm 1993 ; 50: 698-702.
2139 Rivista Serrurier C, Chenot ED, Vigneron J, May I, Demor? B.
Assessment of injectable drug’s administration in two intensive care units and determination of potential physico-chemical incompatibilities.
EJHP Science 2006 ; 12,5: 96-99.
3379 Rivista Fox L.M, Wilder A.G, Foushee J.A.
Physical compatibility of various drugs with neonatal total parenteral nutrient solution during simulated Y-site administration.
Am J Health-Syst Pharm 2013 ;70:520-524.
3541 Laboratorio Rifampicin (Rifadin®) – Summary of Product Characteristics
Sanofi 2011
4405 Rivista Ezquer-Garin C, Ferriols-Lisart R, Martinez-López LM, Sangrador-Pelluz C, Nicolás-Picó J, Alós-Almiñana M.
Stability of tedizolid phosphate-sodium rifampicin and tedizolid phosphate-meropenem admixtures in intravenous infusion bags stored at different temperatures
Pharmazie 2020 ; 75: 172-176.
4543 Rivista Senarathna G, Strunk T, Petrovski M, Batty K.
Physical compatibility of pentoxifylline and intravenous medications.
Archives of Disease in Childhood 2018 ;104:292–295.
4837 Rivista De Silva, D.T.N Petrovski M, Strunk T, Mukadam N, Page‑Sharp N, Moore B.R, Batty K.T.
Physicochemical compatibility of caffeine citrate and caffeine base injections with parenteral medications used in neonatal intensive care settings.
Eur J Clin Pharmacol 2024 ; 80:1079–1087.

  Mentions Légales