Zadnji put ažurirano :
03/05/2024
Bibliografija   Bibliografija 2184  
Vrsta : Časopis
Weblink : https://www.sciencedirect.com/science/article/pii/S0885392406004714

Istraživačkih timova : Amsterdam - Academic Medical center, Department of Pharmacy
Autor : Vranken JH, van Kan HJM, ven der Vegt MH.
Naslov : Stability and compatibility of a meperidine-clonidine mixture in portable pump reservoirs for the management of cancer pain syndromes.
Référence : J Pain Symptom Manage ; 32, 4: 297-299. 2006

Razina dokaza : 
Razina dokaza D
Fizička stabilnost : 
Vizualni aspekt 
Kemijska stabilnost : 
Tekućinska kromatografija visoke djelotvornosti - detektor s diodnim nizom
Ostale metode : 
Mjerenje pH 
Komentari : 

Liste
InjekcijaClonidine hydrochloride Antihipertenzor
Kompatibilan 0.003 mg/ml + InjekcijaPethidine hydrochloride 8 mg/ml + Natrijumkorid 0,9%
InjekcijaPethidine hydrochloride Analgetik
Kompatibilan 8 mg/ml + InjekcijaClonidine hydrochloride 0.003 mg/ml + Natrijumkorid 0,9%
Stabilnost mješavine
Polivinilklorid Natrijumkorid 0,9% 25°C Svjetlost
Injekcija Pethidine hydrochloride 8 mg/ml
Injekcija Clonidine hydrochloride 0,003 mg/ml
21 Dan