Última actualização :
03/05/2024
Droga contra o câncer   Thiotepa  
Injetável
Estabilidade em soluções simples Estabilidade em misturas Factores que afectam a sua estabilidade Compatibilidade Método de administração Bibliografía Pdf
   Estrutura química  

Nomes comerciais nos diversos países   Nomes comerciais nos diversos países     

OS NOMES COMERCIAIS SÃO INDICATIVOS E OS EXCIPIENTES DA FORMULAÇÃO PODEM SER DIFERENTES CONFORME O PAÍS E FABRICANTE.

Bedford Nova Zelândia
Ledertepa Países Baixos
Oncotiotepa Espanha
Thioplex Itália
Thiotepa Alemanha, Australia, Austria, Estados Unidos de América, Gran-bretanha, Irlanda, Suècia
Bibliografía   Injetável   Bibliografía : Thiotepa  
Tipo Publicação
3 Jornal Trissel LA, Martinez JF.
Compatibility of amifostine with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1995 ; 52: 2208-2212.
81 Jornal Trissel LA, Martinez JF.
Compatibility of piperacillin sodium plus tazobactam with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1994 ; 51: 672-678.
84 Jornal Trissel LA, Martinez JF.
Visual, turbidimetric, and particle-content assessment of compatibility of vinorelbine tartrate with selected drugs during simulated Y-site injection.
Am J Hosp Pharm 1994 ; 51: 495-499.
99 Jornal Trissel LA, Martinez JF.
Compatibility of aztreonam with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1995 ; 52: 1086-1090.
169 Jornal Trissel LA, Martinez JF.
Physical compatibility of melphalan with selected drugs during simulated Y-site administration.
Am J Hosp Pharm 1993 ; 50: 2359-2363.
182 Jornal Trissel LA, Gilbert DL, Martinez JF.
Compatibility of granisetron hydrochloride with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 56-60.
244 Jornal Trissel LA, Martinez JF.
Compatibility of filgrastim with selected drugs during simulated Y-site administration.
Am J Hosp Pharm 1994 ; 51: 1907-1913.
249 Jornal Trissel LA, Martinez JF.
Compatibility of thiotepa (lyophilized) with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1996 ; 53: 1041-1045.
302 Jornal Murray KM, Erkkila D, Gombotz WR, Pankey S.
Stability of thiotepa (lyophilized) in 0.9% sodium chloride injection.
Am J Health-Syst Pharm 1997 ; 54: 2588-2591.
307 Jornal Trissel LA, Martinez JF.
Compatibility of allopurinol sodium with selected drugs during simulated Y-site administration.
Am J Hosp Pharm 1994 ; 51: 1792-1799.
905 Jornal Trissel LA, Martinez JF.
Screening teniposide for Y-site physical incompatibilities.
Hosp Pharm 1994 ; 29: 1010-1017.
1410 Jornal Trissel LA, Martinez JF, Simmons M.
Compatibility of etoposide phosphate with selected drugs during simulated Y-site injection.
J Am Pharm Assoc 1999 ; 39: 141-145.
1423 Jornal Trissel LA, Martinez JF, Gilbert DL.
Compatibility of gemcitabine hyrochloride with 107 selected drugs during simulated Y-site injection.
J Am Pharm Assoc 1999 ; 39: 514-518.
3603 Laboratório Thiotepa (Tepadina®) - Summary of Product Characteristics
Adienne Pharma Biotech 2011
4677 Poster Linxweiler H, Thiesen J, Krämer I.
Physicochemical stability of diluted "Thiotepa Riemser" infusion solutions in prefilled 5% glucose infusion bags.
EAHP Congress Vienna 2022
4748 Jornal Linxweiler H, Thiesen J, Krämer I.
Physicochemical Stability of Generic Thiotepa Concentrate and Ready-to-Administer Infusion Solutions for Conditioning Treatment.
Pharmaceutics 2023 ,15, 309.