Son güncelleme :
03/05/2024
Analjezik   Oxycodone hydrochloride  
Enjeksiyon
Merhem
Çözeltilerin stabilitesi Karışımlardaki stabilitesi Stabiliteyi etkileyen faktörler Uyumluluk Uygulama yöntemi Kaynaklar Pdf
   Kimyasal yapı   

Ticari isim   Ticari isim     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Endocodil Meksika
Oxanest Finlandiya
Oxycodone Fransa
Oxyfast Japonya
Oxygesic Almanya
Oxynorm Belçika, Büyük Britanya, Finlandiya, Fransa, İspanya, İsveç, İsviçre, İzlanda, Malezya, Norveç, Yeni Zelanda
Kaynaklar   Enjeksiyon    Kaynaklar : Oxycodone hydrochloride  
Tip Yayın
1726 Dergi Turnbull K, Bielech M, Walker SE, Law S.
Stability of oxycodone hydrochloride for injection in dextrose and saline solutions.
Can J Hosp Pharm 2002 ; 55: 272-277.
2125 Dergi Gardiner PR.
Compatibility of an injectable oxycodone formulation with typical diluents, syringes, tubings, infusion bags and drugs for potential co-administration.
Hospital Pharmacist 2003 ; 10: 354-361.
2199 Laboratuar Chlorhydrate d'oxycodone (Oxynorm®)– Résumé des caractéristiques du produits
Mundipharma 2007
2366 Afiş M?ller S, Trittler R, Schubert R.
Oxycodon-Metamizol in PCA pumpen : Kompatibel?
ADKA Congress 2009
2900 Dergi Hines S, Pleasance S.
Compatibility of an injectable high strength oxycodone formulation with typical diluents, syringes, tubings,infusion bags and drugs for potential co-administration.
EJHP 2009 ; 15, 5: 32-38.
3126 Dergi Amri A, Achour AB, Chachaty E, Mercier L, Bourget P, Paci A.
Microbiological and Physicochemical Stability of Oxycodone Hydrochloride Solutions for Patient-Controlled Delivery Systems.
J Pain Symptom Manage 2010 ; 40, 1: 87-94.
3791 Afiş Sadou Yaye H, Burtet E, Hamel C, Aljhni R, Gard C, Tilleul P.
Étude de la compatibilité physico-chimique du phloroglucinol injectable durant les mélanges au sein des tubulures en Y.
Apifh Congress, Paris November 2014 2014
4143 Dergi Daouphars M, Hervou?t C.H, Bohn P, Martin D, Rouvet J, Basuyau F, Varin R.
Physicochemical stability of oxycodone-ketamine solutions in polypropylene syringe and polyvinyl chloride bag for patient-controlled analgesia use.
EJHP 2016 ; 25, 4
4666 Dergi Lee C.H, Kim A.R, Lee M.K, Oh J.S, Lee D.K, Choi S.S.
Intravenous patient-controlled analgesia: in vitro stability profiles of mixtures containing fentanyl, hydromorphone, oxycodone, nefopam, ondansetron, and ramosetron.
J Anal Sci Tech 2020 ; 11: 32.
4768 Dergi Kondo M, Genpei M, Watanabe K, Yoshida M, Tagui N, Fukao S, Sugaya K, Takase H.
Y-site injection physical compatibility of remdesivr with select intravenous drugs used in palliative care and for treating coronavirus disease 2019.
Journal of Nippon Medical school 2023

  Mentions Légales