Ultimo aggiornamento :
03/05/2024
Antalgico   Oxycodone hydrochloride  
Iniezione
Unguenti
Stabilità in soluzione Stabilità in miscela Fattori che influenzano la stabilità Compatibilità Metodo di iniezione Bibliografia Pdf
   Struttura chimica  

Nome commerciale   Nome commerciale     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Endocodil Messico
Oxanest Finlandia
Oxycodone Francia
Oxyfast Giappone
Oxygesic Germania
Oxynorm Belgio, Finlandia, Francia, Gran Bretagna, Islanda, Malaysia, Norvegia, Nuova Zelanda, Spagna, Svezia, Svizzera
Bibliografia   Iniezione   Bibliografia : Oxycodone hydrochloride  
Tipo Pubblicazione
1726 Rivista Turnbull K, Bielech M, Walker SE, Law S.
Stability of oxycodone hydrochloride for injection in dextrose and saline solutions.
Can J Hosp Pharm 2002 ; 55: 272-277.
2125 Rivista Gardiner PR.
Compatibility of an injectable oxycodone formulation with typical diluents, syringes, tubings, infusion bags and drugs for potential co-administration.
Hospital Pharmacist 2003 ; 10: 354-361.
2199 Laboratorio Chlorhydrate d'oxycodone (Oxynorm®)– Résumé des caractéristiques du produits
Mundipharma 2007
2366 Poster M?ller S, Trittler R, Schubert R.
Oxycodon-Metamizol in PCA pumpen : Kompatibel?
ADKA Congress 2009
2900 Rivista Hines S, Pleasance S.
Compatibility of an injectable high strength oxycodone formulation with typical diluents, syringes, tubings,infusion bags and drugs for potential co-administration.
EJHP 2009 ; 15, 5: 32-38.
3126 Rivista Amri A, Achour AB, Chachaty E, Mercier L, Bourget P, Paci A.
Microbiological and Physicochemical Stability of Oxycodone Hydrochloride Solutions for Patient-Controlled Delivery Systems.
J Pain Symptom Manage 2010 ; 40, 1: 87-94.
3791 Poster Sadou Yaye H, Burtet E, Hamel C, Aljhni R, Gard C, Tilleul P.
Étude de la compatibilité physico-chimique du phloroglucinol injectable durant les mélanges au sein des tubulures en Y.
Apifh Congress, Paris November 2014 2014
4143 Rivista Daouphars M, Hervou?t C.H, Bohn P, Martin D, Rouvet J, Basuyau F, Varin R.
Physicochemical stability of oxycodone-ketamine solutions in polypropylene syringe and polyvinyl chloride bag for patient-controlled analgesia use.
EJHP 2016 ; 25, 4
4666 Rivista Lee C.H, Kim A.R, Lee M.K, Oh J.S, Lee D.K, Choi S.S.
Intravenous patient-controlled analgesia: in vitro stability profiles of mixtures containing fentanyl, hydromorphone, oxycodone, nefopam, ondansetron, and ramosetron.
J Anal Sci Tech 2020 ; 11: 32.
4768 Rivista Kondo M, Genpei M, Watanabe K, Yoshida M, Tagui N, Fukao S, Sugaya K, Takase H.
Y-site injection physical compatibility of remdesivr with select intravenous drugs used in palliative care and for treating coronavirus disease 2019.
Journal of Nippon Medical school 2023

  Mentions Légales