Ultimele actualizari :
19/11/2024
Citostatic   Irinotecan  
Injectabil
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Asinib Mexic
Axinotecan Germania
Campto Africa de Sud, Austria, Belgia, Croatia, Danemarca, Elvetia, Emiratele Arabe Unite, Finlanda, Franta, Grecia, India, Iran, Irlanda, Italia, Japonia, Luxemburg, Malaezia, Marea Britanie, Maroc, Norvegia, Olanda, Polonia, Portugalia, Spania, Suedia, Tailanda, Tunisia, Turcia, Ungaria
Camptosar Brazilia, Canada, SUA
Irinoliquid Austria
Irnocam Brazilia
Bibliografie   Injectabil   Bibliografie : Irinotecan  
tip publicare
1423 ziar Trissel LA, Martinez JF, Gilbert DL.
Compatibility of gemcitabine hyrochloride with 107 selected drugs during simulated Y-site injection.
J Am Pharm Assoc 1999 ; 39: 514-518.
1617 ziar Li WY, Koda RT.
Stability of irinotecan hydrochloride in aqueous solutions.
Am J Health-Syst Pharm 2002 ; 59: 539-544.
1662 ziar Trissel LA, Saenz CA, Ingram DS, Ogundele AB.
Compatibility screening of oxaliplatin during simulated Y-site administration with other drugs.
J Oncol Pharm Practice 2002 ; 8: 33-37.
1918 ziar Dodds HM, Craik DJ, Rivory LP.
Photodegradation of irinotecan (CPT-11) in aqueous solutions : identification of fluorescent products and influence of solution composition.
J Pharm Sci 1997 ; 86, 12: 1410-1416.
1920 ziar Akimoto K, Kaway A, Ohya K et al.
Photodegradation reactions of CPT-11, a derivative of campothecion, part i: chemical structure of main degradation products in aqueous solution.
Drug Stability 1996 ; 1: 118-122.
1921 ziar Akimoto K, Kawai A, Ohya K.
Photodegradation reactions of CPT-11, a derivative of campothecion, part ii: photodegradation behaviour of CPT-11 in aqueous solution.
Drug Stability 1996 ; 1; 141-146.
1953 ziar Trissel LA, Saenz CA, Ogundele AB, Ingram DS.
Physical compatibility of pemetrexed disodium with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2004 ; 61: 2289-2293.
1976 ziar Trissel LA, Xu QA.
Physical and chemical stability of palonosetron hydrochloride with topotecan hydrochloride and irinotecan hydrochloride during simulated Y-site administration.
Int J Pharm Compound 2005 ; 9, 3: 238-241.
2027 ziar Walker SE, Shirley L, Puodziunas A.
Simulation of Y-site compatibility of irinotecan and leucovorin at room temperature in 5% dextrose in water in 3 different containers.
Can J Hosp Pharm 2005 ; 58: 212-222.
2143 ziar Dodds HM, Robert J, Rivory LP.
The detection of photodegradation products of irinotecan (CPT-11, Campto®, Camptosar®), in clinical studies, using high-performance liquid chromatography/atmospheric pressure chemical ionisation/mass spectrometry.
J Pharm Biomed Anal 1998 ; 17: 785-792.
2168 ziar Ozdemir FA, Anilanmert B, Pekin M.
Spectrophotometric investigation of the chemical compatibility of the anticancer irinotecan-HCl and epirubicin-HCl in the same infusion solution.
Cancer Chemother Pharmacol 2005 ; 56, 5: 529-534.
2241 ziar Thiesen J, Krämer I.
Physicochemical stability of irinotecan injection concentrate and diluted infusion solutions in PVC bags.
J Oncol Pharm Practice 2000 ; 6, 3: 115-121.
2340 ziar Walker S.E, Law S, Puodziunas A.
Simulation of Y-Site Compatibility of Irinotecan and Leucovorin at Room Temperature in 5% Dextrose in Water in 3 Different Containers
Can J Hosp Pharm 2005 ; 58, 4: 212-222.
2671 ziar Kaiser J, Thiesen J, Krämer I.
Stability of irinotecan-loaded eluting beads (DC Bead) used for transarterial chemoembolization.
J Oncol Pharm Practice 2010 ; 16: 53-61.
3129 Laborator Irinotécan (Campto®) – Résumé des caractéristiques du produits
Pfizer 2008
3369 Laborator Levofolinate de sodium Medac - Résumé des caractéristiques du produits
MEDAC France 2011
3670 ziar Sewell G, Massimini M.
Studies on the stability and compatibility of cytotoxic drug infusion with the Tevadaptor system.
EJOP 2014 ; 8, 3: 26-30.
3873 ziar Tan X, Hu J.
Incompatibility between irinotecan and fluorouracil injections
Am J Health-Syst Pharm 2016 ; 73:755.