Ultimo aggiornamento :
27/11/2024
Antimuscarinico   Glycopyrronium bromide  
Iniezione
Soluzione orale
Stabilità in soluzione Stabilità in miscela Fattori che influenzano la stabilità Compatibilità metodo di iniezione Bibliografia pdf
   Struttura chimica  

Nome commerciale   Nome commerciale     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Glycopyrronium bromide injection Gran Bretagna
Robinul Austria, Belgio, Finlandia, Norvegia, Stati Uniti d’America, Svezia
Bibliografia   Iniezione   Bibliografia : Glycopyrronium bromide  
tipo pubblicazione
58 Rivista Parker WA.
Physical compatibility of ranitidine HCl with preoperative injectable medications.
Can J Hosp Pharm 1985 ; 38: 160-161.
300 Rivista Trissel LA, Gilbert DL, Martinez JF.
Compatibility of propofol injectable emulsion with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1287-1292.
404 Rivista Forman JK, Souney PF.
Visual compatibility of midazolam hydrochloride with common preoperative injectable medications.
Am J Hosp Pharm 1987 ; 44: 2298-2299.
660 Rivista Michaels MR, Stauffer GL, Haas DP.
Propofol compatibility with other intravenous drug products - Two new methods of evaluating IV emulsion compatibility.
Ann Pharmacotherapy 1996 ; 30: 228-232.
815 Rivista Stewart JT, Warren FW, King DT, Venkateshwaran TG, Fox JL.
Stability of ondansetron hydrochloride and 12 medications in plastic syringes.
Am J Health-Syst Pharm 1998 ; 55: 2630-2634.
1438 Rivista Souney PF, Solomon MA, Stancher D.
Visual compatibility of cimetidine hydrochloride wih common preoperative injectable medications.
Am J Hosp Pharm 1984 ; 41: 1840-1841.
1756 Rivista Storms ML, Stewart JT, Flynn WW.
Stability of glycopyrrolate injection at ambient temperature and 4°C in polypropylene syringes.
Int J Pharm Compound 2003 ; 7: 65-67.
2113 Rivista Jäppinen A, Kokki H, Naaranlahti TJ, Rasi AS.
Stability of buprenorphine, haloperidol and glycopyrrolate mixture in a 0.9% sodium chloride solution.
Pharm World Sci 1999 ; 21, 6: 272-274.
2286 Rivista Ben M, Trusley C, Kupiec TC, Trissel LA.
Physical and chemical stability of palonosetron hydrochloride with glycopyrrolate and neostigmine during simulated Y-site administration.
Int J Pharm Compound 2008 ; 12, 4: 368-371.
2900 Rivista Hines S, Pleasance S.
Compatibility of an injectable high strength oxycodone formulation with typical diluents, syringes, tubings,infusion bags and drugs for potential co-administration.
EJHP 2009 ; 15, 5: 32-38.
3599 Laboratorio Glycopyrrolate Injection U.S.P. - Summary of Product Characteristics
Amco Amdipharm Mercry 2013
3668 Laboratorio Dexamethasone - Summary of Product Characteristics
Hospira 2015
4828 Rivista Weeks A.L, Sotos J, Woolsey B, Johnston W.M, Cornelius B.W.
The Physical Compatibility of Glycopyrrolate and Rocuronium.
Anesth Prog 2023 ;70(2):53-57.

  Mentions Légales