Last update :
08/05/2024
Antimuscarinic   Glycopyrronium bromide  
Injection
Oral solution
Stability in solutions Stability of mixtures Factors which affect stability Compatibility Route of administration References Pdf
   Chemical structure  

Tradename   Tradename     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Glycopyrronium bromide injection Great Britain
Robinul Austria, Belgium, Finland, Norway, Sweden, United States of America
References   Injection   References : Glycopyrronium bromide  
Type Publication
58 Journal Parker WA.
Physical compatibility of ranitidine HCl with preoperative injectable medications.
Can J Hosp Pharm 1985 ; 38: 160-161.
300 Journal Trissel LA, Gilbert DL, Martinez JF.
Compatibility of propofol injectable emulsion with selected drugs during simulated Y-site administration.
Am J Health-Syst Pharm 1997 ; 54: 1287-1292.
404 Journal Forman JK, Souney PF.
Visual compatibility of midazolam hydrochloride with common preoperative injectable medications.
Am J Hosp Pharm 1987 ; 44: 2298-2299.
660 Journal Michaels MR, Stauffer GL, Haas DP.
Propofol compatibility with other intravenous drug products - Two new methods of evaluating IV emulsion compatibility.
Ann Pharmacotherapy 1996 ; 30: 228-232.
815 Journal Stewart JT, Warren FW, King DT, Venkateshwaran TG, Fox JL.
Stability of ondansetron hydrochloride and 12 medications in plastic syringes.
Am J Health-Syst Pharm 1998 ; 55: 2630-2634.
1438 Journal Souney PF, Solomon MA, Stancher D.
Visual compatibility of cimetidine hydrochloride wih common preoperative injectable medications.
Am J Hosp Pharm 1984 ; 41: 1840-1841.
1756 Journal Storms ML, Stewart JT, Flynn WW.
Stability of glycopyrrolate injection at ambient temperature and 4°C in polypropylene syringes.
Int J Pharm Compound 2003 ; 7: 65-67.
2113 Journal Jäppinen A, Kokki H, Naaranlahti TJ, Rasi AS.
Stability of buprenorphine, haloperidol and glycopyrrolate mixture in a 0.9% sodium chloride solution.
Pharm World Sci 1999 ; 21, 6: 272-274.
2286 Journal Ben M, Trusley C, Kupiec TC, Trissel LA.
Physical and chemical stability of palonosetron hydrochloride with glycopyrrolate and neostigmine during simulated Y-site administration.
Int J Pharm Compound 2008 ; 12, 4: 368-371.
2900 Journal Hines S, Pleasance S.
Compatibility of an injectable high strength oxycodone formulation with typical diluents, syringes, tubings,infusion bags and drugs for potential co-administration.
EJHP 2009 ; 15, 5: 32-38.
3599 Manufacturer Glycopyrrolate Injection U.S.P. - Summary of Product Characteristics
Amco Amdipharm Mercry 2013
3668 Manufacturer Dexamethasone - Summary of Product Characteristics
Hospira 2015

  Mentions Légales