Última actualização :
19/11/2024
Antálgico   Diamorphine hydrochloride  
injetável
Estabilidade em soluções simples Estabilidade em misturas Factores que afectam a sua estabilidade Compatibilidade Método de administração Bibliografía pdf
   estrutura química  

Nomes comerciais nos diversos países   Nomes comerciais nos diversos países     

OS NOMES COMERCIAIS SÃO INDICATIVOS E OS EXCIPIENTES DA FORMULAÇÃO PODEM SER DIFERENTES CONFORME O PAÍS E FABRICANTE.

Diamorphine hydrochloride for injection Gran-bretanha
Diaphin Suicia
Bibliografía   injetável   Bibliografía : Diamorphine hydrochloride  
tipo publicação
339 jornal Kleinberg ML, Duafala ME, Nacov C, Flora KP, Hines J, Davis K, McDaniel A, Scott D.
Stability of heroin hydrochloride in infusion devices and containers for intravenous administration.
Am J Hosp Pharm 1990 ; 47: 377-381.
484 jornal Northcott M, Allsopp MA, Powell H, Sewell GJ.
The stability of carboplatin, diamorphine, 5-fluorouracil and mitozantrone infusions in an ambulatory pump under storage and prolonged “in use” conditions.
J Clin Pharm Ther 1991 ; 16: 123-129.
506 jornal Omar OA, Hoskin PJ, Johnston A, Hanks W, Turner P.
Diamorphine stability in aqueous solution for subcutaneous infusion.
J Pharm Pharmacol 1989 ; 41: 275-277.
512 jornal Barnes AR, Nash S.
Stability of bupivacaine hydrochloride with diamorphine hydrochloride in an epidural infusion.
Pharm World Sci 1995 ; 17: 87-92.
779 jornal Collins AJ, Abethell JA, Holmes SG, Rain R.
Stability of diamorphine hydrochloride with haloperidol in prefilled syringes for continuous subcutaneous administration.
J Pharm Pharmacol 1986 ; 38: 51P.
788 jornal Regnard CFB, Mannix K.
Subcutaneous drug compatibility in palliative care.
Lancet 1989 ; 2 (8670): 1044-1045.
1230 jornal Regnard C, Pashley S, Westrope F.
Anti-emetic / diamorphine mixture compatibility in infusion pumps.
Br J Pharm Pract 1986 ; 8: 218-220.
1232 jornal Beatson C, Taylor A.
A physical compatibility study of furosemide & flucloxacillin injections.
Br J Pharm Pract 1987 ; 9: 223-226, 236.
1288 jornal Allwood MC, Brown PW, Lee M.
Stability of injections containing diamorphine and midazolam in plastic syringes.
Int J Pharm Pract 1994 ; 3: 57-59.
1292 jornal Grassby PF, Roberts DE.
Stability of epidural opiate solutions in 0.9 per cent sodium chloride infusion bags.
Int J Pharm Pract 1995 ; 3: 174-177.
1385 jornal Kirk B, Hain WR.
Diamorphine injection BP incompatibility.
Pharm J 1985 ; 235: 171.
1388 jornal Page J, Hudson S.
Diamorphine hydrochloride compatibility with saline.
Pharm J 1982 ; 228: 238-239.
1886 jornal Allwood MC.
The stability of diamorphine alone and in combinaison with antiemetics in plastic syringes.
Palliative Med 1991 ; 5: 330-333.
2051 jornal Sanchez del Aguila MJ, Jones MF, Vohra A.
Premixed solutions of diamorphine in ropivacaine for epidural anaesthesia: a study on long-term stability.
Br J Anaesth 2003 ; 90: 179-182.
2307 jornal Kreeger L, Cowin P, Noble-Gresty J, Naysmith A.
Epidural diamorphine and bupivacaine stability study.
Palliative Med 1995 ; 9, 4: 315-318.
2308 jornal Hudson S.J, Jones M.F, Nolan S, Ellis H, Duncombe R, Alexander-Williams J.M.
Stability of premixed syringes of diamorphine and hyperbaric bupivacaine.
Int J Obstet Anesth 2005 ; 14, 4: 284-287.
2404 jornal Fielding H, Kyaterekera , Skellern GG, Tettey JN, McDade JR, ZMsuya Z, Watson DG, Urie J.
The compatibility and stability of octreotide acetate in the presence of diamorphine hydrochloride in polypropylene syringes
Palliative Med 2000 ; 14: 205-208.
3184 Laboratório
Hyaluronidase (Hyalase®) - Summary of Product characteristics.
CP Pharmaceuticals 2005
3504 Laboratório Parecoxib (Dynastat®) - Summary of Product Characteristics
Pfizer 2012

  Mentions Légales