viimane versioon :
19/11/2024
analgeetikum   Diamorphine hydrochloride  
Süsteravim
Stabiilsus lahustes Stabiilsust mõjutavad tegurid stabiilsust mõjutavad faktorid Sobimatus Manustamis viis Viited pdf
   keemiline struktuur  

Kaubanduslikud nimed erinevates maades   Kaubanduslikud nimed erinevates maades     

Preparaatide nimed on näitlikud ja abianete sisaldus võib erineda sõltuvalt riigist ja laborist

Diamorphine hydrochloride for injection Suurbritannia
Diaphin Sveits
Viited   Süsteravim   Viited : Diamorphine hydrochloride  
tüüp avaldamine
339 ajaleht Kleinberg ML, Duafala ME, Nacov C, Flora KP, Hines J, Davis K, McDaniel A, Scott D.
Stability of heroin hydrochloride in infusion devices and containers for intravenous administration.
Am J Hosp Pharm 1990 ; 47: 377-381.
484 ajaleht Northcott M, Allsopp MA, Powell H, Sewell GJ.
The stability of carboplatin, diamorphine, 5-fluorouracil and mitozantrone infusions in an ambulatory pump under storage and prolonged “in use” conditions.
J Clin Pharm Ther 1991 ; 16: 123-129.
506 ajaleht Omar OA, Hoskin PJ, Johnston A, Hanks W, Turner P.
Diamorphine stability in aqueous solution for subcutaneous infusion.
J Pharm Pharmacol 1989 ; 41: 275-277.
512 ajaleht Barnes AR, Nash S.
Stability of bupivacaine hydrochloride with diamorphine hydrochloride in an epidural infusion.
Pharm World Sci 1995 ; 17: 87-92.
779 ajaleht Collins AJ, Abethell JA, Holmes SG, Rain R.
Stability of diamorphine hydrochloride with haloperidol in prefilled syringes for continuous subcutaneous administration.
J Pharm Pharmacol 1986 ; 38: 51P.
788 ajaleht Regnard CFB, Mannix K.
Subcutaneous drug compatibility in palliative care.
Lancet 1989 ; 2 (8670): 1044-1045.
1230 ajaleht Regnard C, Pashley S, Westrope F.
Anti-emetic / diamorphine mixture compatibility in infusion pumps.
Br J Pharm Pract 1986 ; 8: 218-220.
1232 ajaleht Beatson C, Taylor A.
A physical compatibility study of furosemide & flucloxacillin injections.
Br J Pharm Pract 1987 ; 9: 223-226, 236.
1288 ajaleht Allwood MC, Brown PW, Lee M.
Stability of injections containing diamorphine and midazolam in plastic syringes.
Int J Pharm Pract 1994 ; 3: 57-59.
1292 ajaleht Grassby PF, Roberts DE.
Stability of epidural opiate solutions in 0.9 per cent sodium chloride infusion bags.
Int J Pharm Pract 1995 ; 3: 174-177.
1385 ajaleht Kirk B, Hain WR.
Diamorphine injection BP incompatibility.
Pharm J 1985 ; 235: 171.
1388 ajaleht Page J, Hudson S.
Diamorphine hydrochloride compatibility with saline.
Pharm J 1982 ; 228: 238-239.
1886 ajaleht Allwood MC.
The stability of diamorphine alone and in combinaison with antiemetics in plastic syringes.
Palliative Med 1991 ; 5: 330-333.
2051 ajaleht Sanchez del Aguila MJ, Jones MF, Vohra A.
Premixed solutions of diamorphine in ropivacaine for epidural anaesthesia: a study on long-term stability.
Br J Anaesth 2003 ; 90: 179-182.
2307 ajaleht Kreeger L, Cowin P, Noble-Gresty J, Naysmith A.
Epidural diamorphine and bupivacaine stability study.
Palliative Med 1995 ; 9, 4: 315-318.
2308 ajaleht Hudson S.J, Jones M.F, Nolan S, Ellis H, Duncombe R, Alexander-Williams J.M.
Stability of premixed syringes of diamorphine and hyperbaric bupivacaine.
Int J Obstet Anesth 2005 ; 14, 4: 284-287.
2404 ajaleht Fielding H, Kyaterekera , Skellern GG, Tettey JN, McDade JR, ZMsuya Z, Watson DG, Urie J.
The compatibility and stability of octreotide acetate in the presence of diamorphine hydrochloride in polypropylene syringes
Palliative Med 2000 ; 14: 205-208.
3184 Labor
Hyaluronidase (Hyalase®) - Summary of Product characteristics.
CP Pharmaceuticals 2005
3504 Labor Parecoxib (Dynastat®) - Summary of Product Characteristics
Pfizer 2012