种类 : |
文献 |
|
研究小組 : |
Birmingham - Queen Elisabeth Hospital, Pharmacy Department |
作者 : |
Wood MJ, Lund R, Beavan M. |
标题 : |
Stability of vancomycin in plastic syringes measured by high-performance liquid chromatography. |
引用文献 : |
J Clin Pharm Ther ; 20: 319-325. 1995 |
|
可信 : |
|
物理稳定性 : |
|
化学稳定性 : |
|
其它方法 : |
|
评论 : |
已确认的降解产物 | 重复性/再现/标准值范围:结果未提供或结果超出了规定值 |
|
药品清单
Vancomycin hydrochloride
|
|
|
|
|
10 mg/ml |
25°C |
|
29 |
|
|
|
|
|
|
10 mg/ml |
4°C |
|
84 |
|
|
|
|
|
|
10 mg/ml |
25°C |
|
33 |
|
|
|
|
|
|
10 mg/ml |
4°C |
|
84 |
|
|
|
|
|
|
10 mg/ml |
25°C |
|
47 |
|
|
|
|
|
|
10 mg/ml |
4°C |
|
84 |
|
|
|
|
|
|
10 mg/ml |
4°C |
|
84 |
|
|
|
|
|
|
10 mg/ml |
25°C |
|
62 |
|
|
|
|
|
|
10 mg/ml |
25°C |
|
55 |
|
|
|
|
|