Ultimele actualizari :
26/03/2025
Bibliografie   Bibliografie 4904  
tip : ziar
Internet legătură într- : https://doi.org/10.1136/ejhpharm-2023-003689

Echipe de cercetare : Montreal - Centre hospitalier Sainte Justine
Autor : Hamelin A, Thompson-Desormeaux F, Elliott A, Friciu M, Forest JM, Leclair G.
titlu : Y-site simulation compatibility study of 10% calcium salts with various injectable solutions during toxicological resuscitation.
Référence : EJHP 2023

Nivelul dovezii : 
stabilitatea fizică : 
Stabilitate chimică : 
alte metode : 
Comentarii : 

Listele
InjectabilCalcium chloride electrolit
Compatibil 100 mg/ml + InjectabilInsulin 100 UI/ml + fara
InjectabilCalcium gluconate electrolit
Compatibil 100 mg/ml + InjectabilInsulin 100 UI/ml + fara
InjectabilInsulin Hipoglicemiant
Compatibil 100 UI/ml + InjectabilCalcium chloride 100 mg/ml + fara
Compatibil 100 UI/ml + InjectabilCalcium gluconate 100 mg/ml + fara