Last update :
03/05/2024
References   References 3574  
Type : Manufacturer

Research teams :
Authors :
Title : Ondansetron - Résumé des caractéristiques du produit
Reference : Accord Healthcare France SAS 2013

Level of Evidence : 
Manufacturer's stability data
Physical stability : 
Chemical stability : 
Other methods : 
Comments : 

List of drugs
InjectionCarboplatin Anticancer drug
Compatible 0,18 >> 9,9 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml
InjectionCeftazidime Antibiotic
Compatible 200 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml + Water for Injection
InjectionCisplatin Anticancer drug
Compatible < 0,48 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml
InjectionCyclophosphamide Anticancer drug
Compatible 20 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml + Water for Injection
InjectionDoxorubicin hydrochloride Anticancer drug
Compatible 2 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml + Water for Injection
InjectionEtoposide Anticancer drug
Compatible 0,14 >> 0,25 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml
InjectionFluorouracil Anticancer drug
Incompatible > 0,8 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml
Compatible < 0,8 mg/ml + InjectionOndansetron hydrochloride 0,016 >> 0,16 mg/ml
InjectionOndansetron hydrochloride Antiemetic
Factors which affect stability Solvent NaHCO3 Induces Degradation
Compatible 0,016 >> 0,16 mg/ml + InjectionCarboplatin 0,18 >> 9,9 mg/ml
Compatible 0,016 >> 0,16 mg/ml + InjectionCeftazidime 200 mg/ml + Water for Injection
Compatible 0,016 >> 0,16 mg/ml + InjectionCisplatin < 0,48 mg/ml
Compatible 0,016 >> 0,16 mg/ml + InjectionCyclophosphamide 20 mg/ml + Water for Injection
Compatible 0,016 >> 0,16 mg/ml + InjectionDoxorubicin hydrochloride 2 mg/ml + Water for Injection
Compatible 0,016 >> 0,16 mg/ml + InjectionEtoposide 0,14 >> 0,25 mg/ml
Incompatible 0,016 >> 0,16 mg/ml + InjectionFluorouracil > 0,8 mg/ml
Compatible 0,016 >> 0,16 mg/ml + InjectionFluorouracil < 0,8 mg/ml
Incompatible + InjectionSodium bicarbonate
Incompatible + NaHCO3
InjectionSodium bicarbonate Electrolyte
Incompatible + InjectionOndansetron hydrochloride

  Mentions Légales