Ultimele actualizari :
06/01/2025
Bibliografie   Bibliografie 4835  
tip : ziar
Internet legătură într- : https://doi.org/10.1186/s40635-020-00311-5

Echipe de cercetare : Nottingham - School of Medicine, University of Nottingham, UK
Autor : Hammond S, Wignell A, Cooling P, Barrett D.A, Davies P.
titlu : Plasma-Lyte 148 and Plasma-Lyte 148 + 5% glucose compatibility with commonly used critical care drugs.
Référence : Intensive Care Medecine Experimental 8:25. 2020

Nivelul dovezii : 
stabilitatea fizică : 
Stabilitate chimică : 
alte metode : 
Comentarii : 

Listele
InjectabilDobutamine hydrochloride Cardiotonic
Compatibil 2 mg/ml + Plasmalyte 148 (Baxter)
Compatibil 2 mg/ml +  Plasmalyte 148 dextrose 5% (Baxter)
InjectabilDopamine hydrochloride Cardiotonic
Compatibil 4 mg/ml + Plasmalyte 148 (Baxter)
Compatibil 4 mg/ml +  Plasmalyte 148 dextrose 5% (Baxter)
InjectabilEpinephrine hydrochloride Simpatomimetic
Compatibil 30 µg/ml + Plasmalyte 148 (Baxter)
Compatibil 30 µg/ml +  Plasmalyte 148 dextrose 5% (Baxter)
InjectabilMidazolam hydrochloride Anxiolitic
Incompatibil 3 mg/ml + Plasmalyte 148 (Baxter)
Incompatibil 3 mg/ml +  Plasmalyte 148 dextrose 5% (Baxter)
InjectabilMilrinone lactate Cardiotonic
Compatibil 0,2 mg/ml + Plasmalyte 148 (Baxter)
Compatibil 0,2 mg/ml +  Plasmalyte 148 dextrose 5% (Baxter)

  Mentions Légales