Last update :
27/11/2024
References   References 1931  
Type : Journal

Research teams : Ottawa - The Ottawa Hospital, department of Pharmacy
Authors : Donnely RF.
Title : Physical compatibility and chemical stability of bupivacaine and hydromorphone in polypropylene syringes.
Reference : Can J Hosp Pharm ; 4: 230-235. 2004

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
injectionBupivacaine hydrochloride Local anesthetic
Compatible 2,5 mg/ml + injectionHydromorphone hydrochloride 0,02 & 0,04 mg/ml + Sodium chloride 0,9%
injectionHydromorphone hydrochloride Analgesic
Compatible 0,02 & 0,04 mg/ml + injectionBupivacaine hydrochloride 2,5 mg/ml + Sodium chloride 0,9%
Stability of mixtures
Polypropylen Syringe Sodium chloride 0,9% 22°C Light
injection Hydromorphone hydrochloride 0,02 & 0,04 mg/ml
injection Bupivacaine hydrochloride 2,5 mg/ml
91 Day
Polypropylen Syringe Sodium chloride 0,9% 6°C Protect from light
injection Hydromorphone hydrochloride 0,02 & 0,04 mg/ml
injection Bupivacaine hydrochloride 2,5 mg/ml
91 Day

  Mentions Légales