Last update :
28/04/2024
Antibiotic   Tedizolid phosphate  
Injection
Stability in solutions Stability of mixtures Factors which affect stability Compatibility Route of administration References Pdf
   Chemical structure  

Tradename   Tradename     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Sivextro Chile, France, Germany, Great Britain, Mexico, Romania, Spain, Switzerland
Stability in solutions   Injection   Stability in solutions : Tedizolid phosphate     
Container Solvent Concentration Temperature Storage Duration of stability References
Glass Water for Injection 50 mg/ml 2-8°C Not specified
24 Hour
3753
Manufacturer's stability data

Glass Water for Injection 50 mg/ml 25°C Not specified
24 Hour
3753
Manufacturer's stability data

Not specified Sodium chloride 0,9% 0,8 mg/ml 2-8°C Not specified
24 Hour
3753
Manufacturer's stability data

Not specified Sodium chloride 0,9% 0,8 mg/ml 25°C Not specified
24 Hour
3753
Manufacturer's stability data