Viimeisin päivitys :
19/11/2024
Muskariinireseptorisalpaajat   Scopolamine N-butyl bromide  
Injektioneste
Stabilius liuoksessa Stabilius seoksissa Tekijät, jotka vaikuttavat stabiliuteen Yhteensopivuus Antotapa Viitteet pdf
   Kemiallinen rakenne  

Kauppanimi   Kauppanimi     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Buscapina Espanja
Buscolysin Puola
Buscopan Australia, Belgia, Brasilia, Egypti, Hollanti, Islanti, Itävalta, Kanada, Luxemburg, New Zealand, Norja, Portugali, Ruotsi, Saksa, Suomi, Sveitsi, Tunisia, Turkki, Yhdistyneet arabiemiirikunnat
Butilbromuro de hioscina Argentiina, Kolumbia
Cifespasmo Argentiina
Colobolina Argentiina
Dolopina Ecuador
Escopolamina N butyl bromuro Chile
Hiocin Venezuela
Hioscina Argentiina, Kolumbia, Marokko
Hioscina butil bromuro Kolumbia, Marokko
Hyocidic Iran
Hyoscine Australia
Hyoscine hydrobromide Kanada
Hyotex Iran
Pasmodina Drawer Argentiina
Rupe N Argentiina
Scoburen Ranska
Selpirans Venezuela
Spasmopan Tunisia
Xemol Turkki
Viitteet   Injektioneste   Viitteet : Scopolamine N-butyl bromide  
tyyppi julkaisu
1230 Lehti Regnard C, Pashley S, Westrope F.
Anti-emetic / diamorphine mixture compatibility in infusion pumps.
Br J Pharm Pract 1986 ; 8: 218-220.
1232 Lehti Beatson C, Taylor A.
A physical compatibility study of furosemide & flucloxacillin injections.
Br J Pharm Pract 1987 ; 9: 223-226, 236.
1405 Lehti Peterson GM, Miller KA, Galloway JG, Dunne PF.
Compatibility and stability of fentanyl admixtures in polypropylene syringes.
J Clin Pharm Ther 1998 ; 23: 67-72.
1757 Lehti Schrijvers D, Tai-Apin C, De Smet MC, Cornil P, Vermorken JB, Bruyneel P.
Determination of compatibility and stability of drugs used in palliative care.
J Clin Pharm Ther 1998 ; 23: 311-314.
1847 Lehti Anacardo R, Perilli O, Bartolini S, Gentile MM, Mazzeo P, Carlucci G.
Physicochemical compatibility between ketoprofen kysine salt injections (Artrosilene®) and pharmaceutical products frequently used for combined therapy by intravenous administration.
J Pharm Biomed Anal 2003 ; 32, 6: 1235-1241.
1966 Lehti Barcia E, Reyes R, Azuara L, Sànchez Y, Negro S.
Stability and compatibility of binary mixtures of morphine hydrochloride with hyoscine-n-butyl bromide.
Support Care Cancer 2005 ; 13, 4: 239-245.
1970 Lehti Barcia E, Reyes R, Azuara M.L, S?nchez Y, Negro S.
Compatibility of haloperidol and hyoscine-N-butyl bromide in mixtures for subcutaneous infusion to cancer patients in palliative care.
Support Care Cancer 2003 ; 11, 2: 107-113.
1971 Lehti Azuara ML, Sanchez Y, Reyes R, Barcia E.
Physical compatibility and in vivo evaluation of drug mixtures forsubcutaneous infusion to cancer patients in palliative care.
Support Care Cancer 2001
2055 Lehti Negro S, Reyes R, Azuara ML, Sanchez Y, Barcia E.
Morphine, haloperidol and hyoscine N-butyl bromide combined in sc infusion solutions : compatibility and stability evaluation in terminal oncology patients.
Int J Pharm 2006 ; 307: 278-284.
2125 Lehti Gardiner PR.
Compatibility of an injectable oxycodone formulation with typical diluents, syringes, tubings, infusion bags and drugs for potential co-administration.
Hospital Pharmacist 2003 ; 10: 354-361.
2176 Lehti Barcia E, Martin A, Azuara ML, Sanchez Y, Negro S.
Tramadol and hyoscine N-butyl bromide combined in infusion solutions: compatibility and stability.
Support Care Cancer 2007 ; 15: 57-62.
2900 Lehti Hines S, Pleasance S.
Compatibility of an injectable high strength oxycodone formulation with typical diluents, syringes, tubings,infusion bags and drugs for potential co-administration.
EJHP 2009 ; 15, 5: 32-38.
3132 Lehti Negro S, Martin A, Azuara L, Sanchez Y, Barcia E.
Compatibility and stability of ternary admixtures of tramadol, haloperidol, and hyoscine.
J Palliat Med 2010 ; 13, 3: 273-277.
4404 ilmoitus Müller U, Haller F, Wiedemeier P, Steuer C.
Compatibility studies of seven commonly used drugs for parenteral administration in palliative care.
JFSPH 2019 2019

  Mentions Légales