Ultimele actualizari :
29/10/2024
Citostatic   Gemcitabine hydrochloride  
Injectabil
Stabilitatea in solutie Stabilitatea in amestec Factorii care influenteaza stabilitatea Compatibilitate Microunde Bibliografie pdf
   Formula chimica  

Denumirea comerciala   Denumirea comerciala     

Trade names are indicative and excipients composition can be different depending on the country and manufacturers

Accogem Mexic
Antoril Argentina
Axigem Germania
Bendacitabin Germania
Binoptos Mexic
Celzar Peru
Dercin Romania
Dhacibine Malaezia
Emcitab Columbia
Eriogem Argentina, Ecuador
Fotinex Argentina, Peru
Gebina Argentina
Gebitan Columbia
Gembio Argentina, Chilli, Ecuador
Gemcimira Chilli, Peru
Gemcit Portugalia
Gemcitabin Germania
Gemcitac Chilli
Gemko Turcia
Gemsibin Turcia
Gemsol Austria
Gemtero Chilli, Peru
Gemzar Africa de Sud, Australia, Austria, Belgia, Brazilia, Canada, Chilli, Columbia, Croatia, Danemarca, Ecuador, Egipt, Elvetia, Emiratele Arabe Unite, Finlanda, Franta, Germania, Grecia, Iran, Irlanda, Islanda, Italia, Luxemburg, Malaezia, Marea Britanie, Maroc, Mexic, Norvegia, noua Zeelandă, Olanda, Polonia, Portugalia, Romania, Slovenia, Spania, SUA, Suedia, Tailanda, Tunisia, Turcia, Ungaria, Venezuela
Gentabin Columbia
Haxanit Argentina, Peru
Lenfotabin Mexic
Bibliografie   Injectabil   Bibliografie : Gemcitabine hydrochloride  
tip publicare
1422 ziar Xu QA, Zhang Y, Trissel LA.
Physical and chemical stability of gemcitabine hydrochloride solutions.
J Am Pharm Assoc 1999 ; 39: 509-513.
1423 ziar Trissel LA, Martinez JF, Gilbert DL.
Compatibility of gemcitabine hyrochloride with 107 selected drugs during simulated Y-site injection.
J Am Pharm Assoc 1999 ; 39: 514-518.
1501 ziar Beitz C, Bertsch T, Hannak D, Schrammel W, Einberger C, Wehling M.
Compatibility of plastics with cytotoxic drug solutions - comparison of polyethylene with other container materials.
Int J Pharm 1999 ; 185: 113-121.
1520 Laborator Etude de stabilité des médicaments en Ecoflac®
B Braun 2001
1611 ziar Chalmers JR, Bobek MB, Militello MA.
Visual compatibility of amiodarone hydrochloride injection with various intravenous drugs.
Am J Health-Syst Pharm 2001 ; 58: 504-506.
1625 ziar Trissel LA, Saenz C, Williams YW, Ingram D.
Incompatibilities of lansoprazole injection with other drugs during simulated Y-site coadministration.
Int J Pharm Compound 2001 ; 5: 314-321.
1662 ziar Trissel LA, Saenz CA, Ingram DS, Ogundele AB.
Compatibility screening of oxaliplatin during simulated Y-site administration with other drugs.
J Oncol Pharm Practice 2002 ; 8: 33-37.
1663 ziar Ponton JL, Munoz C, Rey M, Val M.
The stability of (lyophilized) gemcitabine in 0.9% sodium chloride injection.
EJHP 2002 ; 1: 23-25.
1925 ziar Trissel LA , Williams KY, Gilbert DL.
Compatibility screening of linezolid injection during simulated Y-site administration with other drugs and infusion solutions.
J Am Pharm Assoc 2000 ; 40: 515-519.
1953 ziar Trissel LA, Saenz CA, Ogundele AB, Ingram DS.
Physical compatibility of pemetrexed disodium with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2004 ; 61: 2289-2293.
1982 ziar Trissel LA, Ogundele AB.
Compatibility of anidulafungin with other drugs during simulated Y-site administration.
Am J Health-Syst Pharm 2005 ; 62: 834-837.
2009 ziar Trissel LA, Zhang Y.
Physical and chemical stability of palonosetron hydrochloride with fluorouracil and with gemcitabine hydrochloride during simulated Y-site administration.
Int J Pharm Compound 2005 ; 2005, 9, 4: 320-322.
2262 ziar Brammer MK, Chan P, Heatherly K, Trusley C, Kupiec TC, Trissel LA, Psathas PA, Gilmor T, Schaufelberger D.
Compatibility of doripenem with other drugs during simulated Y-site administratioN
Am J Health-Syst Pharm 2008 ; 65: 1261-1265.
2344 Laborator Stabilité physico-chimique de la gamme oncologie Ebewe Pharma France après dilution.
Ebewe Pharma 2009
3262 ziar Manners S, Galettis P, de Souza P.
Conditions causing gemcitabine crystallization.
J Oncol Pharm Practice 2011 ; 17, 4: 395-399.
3496 Laborator Gemcitabin Actavis solution - Stability Study
Actavis 2009
3670 ziar Sewell G, Massimini M.
Studies on the stability and compatibility of cytotoxic drug infusion with the Tevadaptor system.
EJOP 2014 ; 8, 3: 26-30.
4310 ziar Mizuta N, Nakagawa T, Yamamoto K, Nishioka T, Kume M, Makimoto H, Yano I, Minami H, Hiral M.
Compatibility and Stability of Nab-Paclitaxel in Combination with Other Drugs.
Kaohsiung J Med Sci 2017 ; 63, 1: E9-E16.
4736 ziar Closset M, Colsoul ML, Goderniaux N, Bihin B, Jamart J, Onorati S, Soumoy L, Hecq JD, Odou P, Galanti L.
An Ultra-High-Performance Chromatography method to study the long term stability of gemcitabine in dose banding conditions.
J Pharm Biomed Anal 2023

  Mentions Légales