Last update :
19/11/2024
References   References 648  
Type : Journal
Web link : http://www.ijpc.com/Abstracts/Abstract.cfm?ABS=415

Research teams : Houston - University of Houston, College of Pharmacy
Authors : Das Gupta V.
Title : Stability of mitomycin aqueous solution when stored in tuberculin syringes.
Reference : Int J Pharm Compound ; 1: 282-283. 1997

Level of Evidence : 
Level of evidence D
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 90% of the initial concentration
Other methods : 
PH measurement 
Comments : 
Repeatability / reproducibility / standard range: results not provided or results outside specified values
Degradation products quantified but not identified

List of drugs
injectionMitomycin Anticancer drug
Stability in solutions Polypropylen Syringe Water for Injection 0,5 mg/ml 25°C Protect from light
7 Day
conflicting data
Stability in solutions Polypropylen Syringe Water for Injection 0,5 mg/ml 4°C Protect from light
28 Day