Last update :
17/12/2025
References   References 621  
Type : Journal

Research teams : Helsinki - Orion Pharmaceutical Co
Authors : Yliruusi JK, Sothmann AG, Laine RH, Rajasilta RA, Kristoffersson ER.
Title : Sorptive loss of diazepam and nitroglycerin from solutions to three types of containers.
Reference : Am J Hosp Pharm ; 39: 1018-1021. 1982

Level of Evidence : 
Physical stability : 
Chemical stability : 
Other methods : 
Comments : 

List of drugs
injectionDiazepam Anxiolytic
Factors which affect stability Container Polyvinyl chloride Induces Absorption
Stability in solutions Glass Sodium chloride 0,9% 0,2 mg/ml 25°C Light
24 Hour
Stability in solutions Glass Glucose 5% 0,2 mg/ml 25°C Light
24 Hour
Stability in solutions Polyethylene Sodium chloride 0,9% 0,2 mg/ml 25°C Light
24 Hour
Stability in solutions Polyethylene Glucose 5% 0,2 mg/ml 25°C Light
24 Hour
injectionNitroglycerin Vasodilator
Factors which affect stability Container Polyvinyl chloride Induces Absorption
Stability in solutions Glass Sodium chloride 0,9% 0,09 mg/ml 25°C Light
24 Hour
Stability in solutions Glass Glucose 5% 0,09 mg/ml 25°C Light
24 Hour
Stability in solutions Polyethylene Sodium chloride 0,9% 0,09 mg/ml 25°C Light
24 Hour
Stability in solutions Polyethylene Glucose 5% 0,09 mg/ml 25°C Light
24 Hour