Last update :
28/04/2024
References   References 48  
Type : Journal

Research teams : Hartford - Hartford Hospital, Department of Pharmacy Services
Authors : Quercia RA, Zhang J, Fau C, Chow MSS.
Title : Stability of granisetron hydrochloride in polypropylene syringes.
Reference : Am J Health-Syst Pharm ; 53: 2744-2746. 1996

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
InjectionGranisetron hydrochloride Antiemetic
Stability in solutions Polypropylen Syringe NaCl 0,9% or Glucose 5% 0,05 & 0,1 mg/ml 24°C Protect from light
14 Day
Stability in solutions Polypropylen Syringe NaCl 0,9% or Glucose 5% 0,05 & 0,1 mg/ml 5°C Protect from light
14 Day