Last update :
19/11/2024
References   References 4661  
Type : Journal

Research teams : Angers - University Hospital of Angers, Pharmacy Department
Authors : Bourcier B, Lagarce R, Lebreton V.
Title : Stability of a high-concentrated aqueous solution of idarubicin stored in a polypropylene syringe for transarterial chemoembolization
Reference : J Pharm Biomed Anal 2022

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
High Performance Liquid Chromatography - mass spectrometry (HPLC-MS)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
injectionIdarubicin hydrochloride Anticancer drug
Stability in solutions Polypropylen Syringe Water for Injection 4 mg/ml 2-8°C Protect from light
7 Day