Zadnji put ažurirano :
18/04/2024
Bibliografija   Bibliografija 4556  
Vrsta : Časopis
Weblink : https://journals.sagepub.com/doi/10.1177/8755122520924767

Istraživačkih timova : Tolède - College of Pharmacy and Pharmaceutical Sciences, The University of Toledo
Autor : Dobson, S.R, Mauro, V.F, Boddu, S.H.S, Churchwell, M.D.
Naslov : The Physical Compatibility of Clinically Used Concentrations of Diltiazem Hydrochloride With Heparin Sodium.
Référence : J Pharm Technol ; 36, 4: 126-129. 2020

Razina dokaza : 
Fizička stabilnost : 
Kemijska stabilnost : 
Ostale metode : 
Komentari : 

Liste
InjekcijaDiltiazem hydrochloride Antiritmičan
Inkompatibilan 5 mg/ml + InjekcijaHeparin sodium 100 UI/ml + Glukoza 5%
Kompatibilan 1 mg/ml + InjekcijaHeparin sodium 100 UI/ml + Glukoza 5%
InjekcijaHeparin sodium Antikoagulant
Inkompatibilan 100 UI/ml + InjekcijaDiltiazem hydrochloride 5 mg/ml + Glukoza 5%
Kompatibilan 100 UI/ml + InjekcijaDiltiazem hydrochloride 1 mg/ml + Glukoza 5%

  Mentions Légales