Last update :
19/11/2024
References   References 4367  
Type : Journal

Research teams : Portland - Legacy Devers Eye Institute
Authors : Kinast R.M, Akula K.K, DeBarber A.E, Barker G.T, Gardiner S.K, Whitson E, Mansberger S.L.
Title : The Degradation of Mitomycin C Under Various Storage Methods.
Reference : J Glaucoma ; 25, 6: 477-481. 2016

Level of Evidence : 
Level of evidence C
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
High Performance Liquid Chromatography - Evaporative Light Scattering detector (HPLC-ELSD)
Stability defined as 95% of the initial concentration
Other methods : 
Comments : 
Degradation products identified and quantified

List of drugs
injectionMitomycin Anticancer drug
Stability in solutions Not specified Water for Injection 0,4 mg/ml -20°C Not specified
23 Day
Stability in solutions Not specified Water for Injection 0,4 mg/ml 25°C Not specified
24 Hour
Stability in solutions Not specified Water for Injection 0,4 mg/ml 4°C Not specified
14 Day

  Mentions Légales