Last update :
28/04/2024
References   References 4284  
Type : Journal

Research teams : Liège - University Hospital of Liège
Authors : Vercheval C, Streel S, Servais A-C, Fillet M, Van Hees T.
Title : Stability of 90 mg/mL cefuroxime sodium solution for administration by continuous infusion.
Reference : Journal of Chemotherapy ; 30, 6-8: 371-374. 2018

Level of Evidence : 
Level of evidence B
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 90% of the initial concentration
Other methods : 
PH measurement 
Comments : 
Degradation products detected but not quantified

List of drugs
InjectionCefuroxime sodium Antibiotic
Factors which affect stability Storage Light Induces Reduced stability
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 90 mg/ml 25°C Protect from light
48 Hour
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 90 mg/ml 4°C Protect from light
14 Day