Last update :
28/04/2024
References   References 4231  
Type : Poster
Icone.pdf
1016Ko

Research teams : Toronto - Sunnybrook Health Sciences Center
Authors : Roxanne Hook, Vera Riss, Erica Scharrer, Shirley Law and Scott E. Walker
Title : Stability of 4 and 10 mcg/mL Remifentanil Solutions Stored in Syringes at Room Temperature (23°C)
Reference : Professional Practice Conference - Canadian Societ 2018

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
Comments : 

List of drugs
InjectionRemifentanil hydrochloride Analgesic
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 4 & 10 µg/ml 23°C Not specified
90 Day

  Mentions Légales