Last update :
27/11/2024
References   References 3922  
Type : Journal
Web link : http://www.pdiconnect.com/content/early/2016/09/06/pdi.2016.00018.abstract?sid=1c1e2dd7-2450-4914-9c7b-447091d56bf7

Research teams : Vienna - University of Vienna, Department of Pharmacognosy
Authors : Wiesholzer, Winter A, Kussmann M, Zeitlinger M, Pichler P, Burgmann H, Reznicek G,Poepp l W.
Title : Compatibility of meropenem with different commercial dialysis solutions.
Reference : Perit Dial Int doi:10.3747/pdi.2016.0001 2016

Level of Evidence : 
Level of evidence D
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - Diode Array detector (HPLD-DAD)
Stability defined as 90% of the initial concentration
Other methods : 
Comments : 
Stability indicating capability inadequately assessed
Repeatability / reproducibility / standard range: results not provided or results outside specified values
No comments for the degradation products

List of drugs
injectionMeropenem Antibiotic
Stability in solutions Polyvinyl chloride Extraneal® (Baxter) 0,25 mg/ml 6°C Protect from light
7 Day
Incompatible + Physionéal® (Baxter)

  Mentions Légales