Last update :
19/11/2024
References   References 3350  
Type : Journal
Web link : http://www.ajhp.org/content/69/22/1999.abstract

Research teams : Ann Arbor - University of Michigan, College of Pharmacy
Authors : Kwiatkowski J.L, Johnson C.E, Wagner D.S.
Title : Extended stability of intravenous acetaminophen in syringes and opened vials.
Reference : Am J Health-Syst Pharm ; 69:1999-2001 2012

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 

List of drugs
injectionParacetamol Analgesic
Stability in solutions Polypropylen Syringe None 10 mg/ml 23-25°C Not specified
84 Hour