Last update :
19/11/2024
References   References 2530  
Type : Journal
Web link : https://ijpc.com/Abstracts/Abstract.cfm?ABS=5100

Research teams : Castellón - Hospital General de Castellón, Servicio de Farmacia
Authors : Bartoll A, Bellés Medall M, Peñarrocha J, Escrig L, Clemente R, Azuara J.
Title : Physicochemical and Microbiological Stability of Vancomycin 10-mg/mL Intravitreal Syringes.
Reference : Int J Pharm Compound ;26,4:330-335 2022

Level of Evidence : 
Level of evidence C
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 90% of the initial concentration
Other methods : 
PH measurement Measurement of osmolality 
Comments : 
Method not shown but the article refers to a validated method
Unencrypted results (eg graphic)

List of drugs
injectionVancomycin hydrochloride Antibiotic
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 10 mg/ml -20°C Protect from light
168 Day
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 10 mg/ml 4°C Protect from light
98 Day

  Mentions Légales