Last update :
22/08/2024
References   References 2404  
Type : Journal
Web link : http://pmj.sagepub.com/cgi/content/abstract/14/3/205

Research teams : Glasgow - University of Strathclyde, Department of Pharmaceutical Sciences
Authors : Fielding H, Kyaterekera , Skellern GG, Tettey JN, McDade JR, ZMsuya Z, Watson DG, Urie J.
Title : The compatibility and stability of octreotide acetate in the presence of diamorphine hydrochloride in polypropylene syringes
Reference : Palliative Med ; 14: 205-208. 2000

Level of Evidence : 
Physical stability : 
Chemical stability : 
Other methods : 
Comments : 

List of drugs
injectionDiamorphine hydrochloride Analgesic
Compatible 6,25 mg/ml + injectionOctreotide acetate 0,0375 mg/ml + Water for Injection
Compatible 6,25 mg/ml + injectionOctreotide acetate 0,1125 mg/ml + Water for Injection
Compatible 6,25 mg/ml + injectionOctreotide acetate 0,075 mg/ml + Water for Injection
Compatible 12,5 mg/ml + injectionOctreotide acetate 0,075 mg/ml + Water for Injection
Compatible 12,5 mg/ml + injectionOctreotide acetate 0,1125 mg/ml + Water for Injection
Compatible 12,5 mg/ml + injectionOctreotide acetate 0,0375 mg/ml + Water for Injection
Compatible 25 mg/ml + injectionOctreotide acetate 0,075 mg/ml + Water for Injection
injectionOctreotide acetate Various
Compatible 0,0375 mg/ml + injectionDiamorphine hydrochloride 6,25 mg/ml + Water for Injection
Compatible 0,1125 mg/ml + injectionDiamorphine hydrochloride 6,25 mg/ml + Water for Injection
Compatible 0,075 mg/ml + injectionDiamorphine hydrochloride 6,25 mg/ml + Water for Injection
Compatible 0,075 mg/ml + injectionDiamorphine hydrochloride 12,5 mg/ml + Water for Injection
Compatible 0,1125 mg/ml + injectionDiamorphine hydrochloride 12,5 mg/ml + Water for Injection
Compatible 0,0375 mg/ml + injectionDiamorphine hydrochloride 12,5 mg/ml + Water for Injection
Compatible 0,075 mg/ml + injectionDiamorphine hydrochloride 25 mg/ml + Water for Injection

  Mentions Légales