Last update :
19/11/2024
References   References 2370  
Type : Journal

Research teams : Belfast - The Queen\'s University of Belfast
Authors : Mawhinney WM, Adair CG, Gorman SP, McClurg B.
Title : Stability of vancomycin hydrochloride in peritoneal dialysis solution
Reference : Am J Hosp Pharm ; 49: 137 - 139. 1992

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 90% of the initial concentration
Other methods : 
Comments : 
No visual inspection
Method not shown but the article refers to a validated method
No comments for the degradation products

List of drugs
injectionVancomycin hydrochloride Antibiotic
Stability in solutions Polyvinyl chloride  Dianéal® PD1 1.36% glucose (Baxter) 0,025 mg/ml 20°C
28 Day
Stability in solutions Polyvinyl chloride  Dianéal® PD1 1.36% glucose (Baxter) 0,025 mg/ml 37°C
7 Day
Stability in solutions Polyvinyl chloride  Dianéal® PD1 1.36% glucose (Baxter) 0,025 mg/ml 4°C Not specified
28 Day
Stability in solutions Polyvinyl chloride Dianéal® PD1 3.86% glucose (Baxter) 0,025 mg/ml 20°C Light
28 Day
Stability in solutions Polyvinyl chloride Dianéal® PD1 3.86% glucose (Baxter) 0,025 mg/ml 37°C Light
5 Day
Stability in solutions Polyvinyl chloride Dianéal® PD1 3.86% glucose (Baxter) 0,025 mg/ml 4°C Not specified
28 Day

  Mentions Légales