Seneste opdatering :
19/11/2024
Bibliografi   Bibliografi 2281  
Type : Journal
Internet-link : http://www.ijpc.com/Abstracts/Abstract.cfm?ABS=2827

forskerhold : Oklaoma City - University of Oklahoma Health Sciences Center, College of Pharmacy
Forfattere : Ben M, Kupiec T, Trusley C, Trisel LA.
Titel : Compatibility and stability of palonosetron hydrochloride with lactated Ringer's, Hetastarch in lactated electrolyte, an mannitol injections during simulated Y-site administration.
Nummer : Int J Pharm Compound ; 12, 5: 460-462. 2008

cotationvaleur : 
Level af bevismateriale A+
fysisk stabilitet : 
visuel undersøgelse turbidimetri partikeltælling 
kemisk stabilitet : 
High Performance Liquid Chromatography - diodearraydetektor (HPLC-DAD)
Stabilitet defineres som 95% af den oprindelige koncentration
andre metoder : 
Kommentarer : 

Lister
InjektionHetastarch Diverse
Kompatibel 60 mg/ml + InjektionPalonosetron hydrochloride 50 µg/ml + Ringer laktat
InjektionMannitol Diverse
Kompatibel 150 mg/ml + InjektionPalonosetron hydrochloride 50 µg/ml + Ingen
InjektionPalonosetron hydrochloride Antiemetisk
Stabilitet i (vandige) opløsninger Glas Ringer laktat 25 µg/ml 25°C Ikke nærmere angivet
4 Time
Kompatibel 50 µg/ml + InjektionHetastarch 60 mg/ml + Ringer laktat
Kompatibel 50 µg/ml + InjektionMannitol 150 mg/ml + Ingen