Last update :
19/11/2024
References   References 223  
Type : Journal
Web link : http://www.ajhp.org/cgi/content/abstract/47/7/1584

Research teams : Bedford Park - Flinders Medical Center, Pain Management Unit
Authors : Kowalski SR, Gourlay GK.
Title : Stability of fentanyl citrate in glass and plastic containers and in a patient-controlled delivery system.
Reference : Am J Hosp Pharm ; 47: 1584-1587. 1990

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
Gas chromatography
Stability defined as 95% of the initial concentration
Other methods : 
Comments : 
No visual inspection

List of drugs
injectionFentanyl citrate Analgesic
Stability in solutions Glass NaCl 0,9% or Glucose 5% 4,55 µg/ml 22°C Light
48 Hour
Stability in solutions Polyvinyl chloride NaCl 0,9% or Glucose 5% 4,55 µg/ml 22°C Light
48 Hour