Last update :
19/11/2024
References   References 2194  
Type : Journal
Web link : http://www.ajhp.org/cgi/content/abstract/64/10/1092

Research teams : DenverDenver - University of Colorado Health Sciences Center
Authors : Kiser TH, Oldland AR, Fish DN.
Title : Stability of phenylephrine hydrochloride injection in polypropylene syringes.
Reference : Am J Health-Syst Pharm ; 64, 10: 1092-1095. 2007

Level of Evidence : 
Level of evidence A
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 
Degradation products not observed in real conditions

List of drugs
injectionPhenylephrine hydrochloride Sympathomimetic
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 0,1 mg/ml -20°C Protect from light
30 Day
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 0,1 mg/ml 23-25°C Light
30 Day
Stability in solutions Polypropylen Syringe Sodium chloride 0,9% 0,1 mg/ml 3-5°C Protect from light
30 Day