Last update :
19/11/2024
References   References 1903  
Type : Journal

Research teams : DallasDallas - Parkland Health and Hospital System
Authors : Gard JW, Alexander JM, Bawdon RE, Albrecht JT.
Title : Oxytocin preparation stability in several common obstetric intravenous solutions.
Reference : Am J Obstet Gynecol ; 186: 496-498. 2002

Level of Evidence : 
Level of evidence D
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Other methods : 
Comments : 
No visual inspection
Stability indicating capability inadequately assessed
Imperfect separation of the internal standard from the product under study or its degradation products, or understudied

List of drugs
injectionOxytocin Various
Stability in solutions Not specified Ringer’s lactate solution 0,02 UI/ml 4°C Not specified
7 Day
Stability in solutions Not specified Ringer’s lactate solution 0,02 UI/ml 4°C Not specified
24 Hour

  Mentions Légales