Last update :
19/11/2024
References   References 1842  
Type : Journal

Research teams : Graz - University of Graz, Department of Pharmaceutical Sciences
Authors : Sadjack A, Wintersteiger R.
Title : Compatibility of morphin, baclofen, floxuridine and fluorouracil in an implantable infusion pump.
Reference : Arzneimittel Forschung ; 45: 93-98. 1995

Level of Evidence : 
Level of evidence C
Physical stability : 
Chemical stability : 
Stability defined as 95% of the initial concentration
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Other methods : 
Comments : 
Repeatability / reproducibility / standard range: results not provided or results outside specified values
Degradation products not observed in real conditions

List of drugs
injectionBaclofen Various
Stability in solutions Not specified None 0,5 mg/ml 37°C Protect from light
56 Day
injectionFloxuridine Anticancer drug
Stability in solutions Not specified None 10 mg/ml 37°C Protect from light
42 Day
injectionFluorouracil Anticancer drug
Stability in solutions Not specified None 50 mg/ml 37°C Protect from light
56 Day
injectionMorphine hydrochloride Analgesic
Stability in solutions Not specified None 10 mg/ml 37°C Protect from light
56 Day

  Mentions Légales