Last update :
19/11/2024
References   References 1715  
Type : Journal
Web link : http://www.ijpc.com/Abstracts/Abstract.cfm?ABS=1459

Research teams : Athens - University of Georgia, College of Pharmacy
Authors : Storms ML, Stewart JT, Warren FW.
Title : Stability of lidocaine hydrochloride injection at ambient temperature and 4°C in polypropylene syringes.
Reference : Int J Pharm Compound ; 6: 388-390. 2002

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 
No visual inspection

List of drugs
injectionLidocaine hydrochloride Local anesthetic
Stability in solutions Polypropylen Syringe None 20 mg/ml 25°C Light
90 Day
Stability in solutions Polypropylen Syringe None 20 mg/ml 25°C Light
90 Day
Stability in solutions Polypropylen Syringe None 20 mg/ml 4°C Protect from light
90 Day