Last update :
28/04/2024
References   References 127  
Type : Journal

Research teams : Dubuque - The Finley Hospital, Department of pharmacy
Authors : Ripley RG, Ritchie DJ, Holstad SG.
Title : Stability of octreotide acetate in polypropylene syringes at 5 and -20°C.
Reference : Am J Health-Syst Pharm ; 52: 1910-1911. 1995

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 90% of the initial concentration
Other methods : 
PH measurement 
Comments : 
No visual inspection

List of drugs
InjectionOctreotide acetate Various
Stability in solutions Polypropylen Syringe None 0,2 mg/ml -20°C Protect from light
60 Day
Stability in solutions Polypropylen Syringe None 0,2 mg/ml 5°C Protect from light
60 Day

  Mentions Légales