Last update :
08/11/2024
References   References 3706  
Type : Journal
Web link : http://www.sefh.es/sefhpublicaciones/revista.php?id=139&anio=2014

Research teams : Alicante - Plataforma de Oncología. Hospital Quirón
Authors : Escudero-Ortiz V, Duart-Duart M.J, P?rez-Ruixo C, P?rez-Ruixo J.J, Valenzuela B.
Title : Estudio de estabilidad de oxaliplatino y doxorrubicina para su administración intraperitoneal con hipertermia.
Reference : Farm Hosp ;38, 3:154-161 2014

Level of Evidence : 
Level of evidence D
Physical stability : 
Visual examination 
Chemical stability : 
High Performance Liquid Chromatography - fluorescence detector
Stability defined as 90% of the initial concentration
Other methods : 
Comments : 
Stability indicating capability inadequately assessed
Repeatability / reproducibility / standard range: results not provided or results outside specified values
No comments for the degradation products

List of drugs
injectionDoxorubicin hydrochloride Anticancer drug
Stability in solutions Glass Glucose 5% 0.015 mg/ml 49°C Protect from light
2 Hour
Compatible 15 mg/ml + injectionOxaliplatin 200 mg/ml + Glucose 5%
injectionOxaliplatin Anticancer drug
Compatible 200 mg/ml + injectionDoxorubicin hydrochloride 15 mg/ml + Glucose 5%