Last update :
19/11/2024
References   References 3309  
Type : Journal
Web link : http://dx.doi.org/10.1136/ejhpharm-2012-000068

Research teams : Milan - Istituto di Ricerche Farmacologiche ‘Mario Negri, Department of Neuroscience
Authors : Zenoni D, Priori G, Bellan C, Invernizzi R.W.
Title : Stability of diluted epinephrine in prefilled syringes for use in neonatology.
Reference : EJHP ;19:378-380 2012

Level of Evidence : 
Level of evidence A+
Physical stability : 
Visual examination Particle counting 
Chemical stability : 
High Performance Liquid Chromatography - Electrochemical detector
Other methods : 
Comments : 
Degradation products not observed in real conditions

List of drugs
injectionEpinephrine hydrochloride Sympathomimetic
Stability in solutions syringe polycarbonate Water for Injection 100 µg/ml 2-8°C Protect from light
172 Day