Last update :
19/11/2024
References   References 1714  
Type : Journal
Web link : http://www.ijpc.com/Abstracts/Abstract.cfm?ABS=586

Research teams : Houston - University of Houston, College of Pharmacy
Authors : Gupta VD.
Title : Stability of ketamine hydrochloride injection after reconstitution in water for injection and storage in 1-ml tuberculin polypropylene syringes for pediatric use.
Reference : Int J Pharm Compound ; 6: 316-317. 2002

Level of Evidence : 
Level of evidence B
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 95% of the initial concentration
Other methods : 
PH measurement 
Comments : 
Stability indicating capability inadequately assessed
No visual inspection

List of drugs
injectionKetamine hydrochloride General anesthetic
Stability in solutions Polypropylen Syringe Water for Injection 10 mg/ml 25°C Not specified
30 Day