Last update :
19/11/2024
References   References 1676  
Type : Journal
Web link : https://doi.org/10.1016/S0378-5173(97)00118-X

Research teams : Clermont-Ferrand - University Hospital Gabriel Monpied, Department of Pharmacy
Authors : Hourcade F, Sautou-Miranda V, Normand B, Laugier M, Picq F, Chopineau J.
Title : Compatibility of granisetron towards glass and plastics and its stability under various storage conditions.
Reference : Int J Pharm ; 154: 95-102. 1997

Level of Evidence : 
Level of evidence D
Physical stability : 
Chemical stability : 
High Performance Liquid Chromatography - ultraviolet detector (HPLC-UV)
Stability defined as 90% of the initial concentration
Other methods : 
Comments : 
Results with high coefficient of variation or not provided, or lack of duplicate analysis of each point
No visual inspection

List of drugs
injectionGranisetron hydrochloride Antiemetic
Stability in solutions Polypropylen Syringe None 1 mg/ml 25°C With or without light
15 Day
Stability in solutions Polypropylen Syringe None 1 mg/ml 4°C Protect from light
15 Day

  Mentions Légales